![RS PRO 917-6298 Instruction Manual Download Page 65](http://html.mh-extra.com/html/rs-pro/917-6298/917-6298_instruction-manual_1496054065.webp)
IIT-2000/2010/5000/5010 Instruction Manual/English
05/08/2015 Version No. 001
63
PASS
HOLD
OFF, ON
4. Press the EDIT/SAVE key to save and exit the
MANU Utility menu.
EDIT/SAVE
Note
The ESC key can be pressed at any time in the MANU Utility
menu to cancel and exit.
Setting FAIL MODE
Background
The FAIL MODE settings only apply to the selected test in
AUTO tests.
FAIL MODE has three options, CONTINUE, HOLD and
STOP.
When FAIL MODE is set to CONTINUE the tester will
continue testing after a FAIL judgment.
When set to HOLD, the tester will hold the test on a FAIL
judgment, and then continue testing after the START key is
pressed.
The STOP mode will completely stop the test after a FAIL
judgment.