background image

Royal Centurian Inc.

ARP-1200M / ARP-1200DM / ARP-1200E / ARP-1200DE

OWNER’S MANUAL

MANUAL DEL PROPIETARIO

PORTABLE AIR CONDITIONER

ACONDICIONADOR DE AIRE PORT

Á

TIL

Read and retain these instructions for future reference

For any Customer Support needs, please choose 

the Customer Support tab on 

www.royalsovereign.com

Summary of Contents for ARP-1200DE

Page 1: ...P 1200DE OWNER S MANUAL MANUAL DEL PROPIETARIO PORTABLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTÁTIL Read and retain these instructions for future reference For any Customer Support needs please choose the Customer Support tab on www royalsovereign com ...

Page 2: ...PORTABLE AIR CONDITIONER Model ARP 1200M ARP 1200DM ARP 1200E ARP 1200DE ...

Page 3: ... in use Do not use in wet environments fig 3 Do not pull the unit by the cord If the supply cord is damaged it must be replaced by an electrician or qualified person to avoid hazard or injury FOR MAXIMUM EFFICENCY Do not exceed the recommended room size 400 sq feet Close doors and windows Keep curtains or blinds closed during the sunniest part of the day Keep filters clean Once room has reached th...

Page 4: ...s 9 Water stopper drainage point PARTS Accessories 10 Air Conditioner adaptor for insertion over hose and into back of the air conditioner 11 Window adaptor for insertion over hose and into window spacer 12 Exhaust hose 13 Extendable window spacer 14 Drain tube for continuous drainage 15 Water tray 16 Remote control for electronic type only 14 12 11 10 15 13 5 1 2 3 4 6 7 8 9 16 ...

Page 5: ... outward adapter 3 Insert the window spacer into window gaps as shown Adjust its length if necessary 4 Slide window across so that the spacer is held securely NOTE Take care to maintain protection against intruders NOTE Install window vent vertically or horizontally depending on window style Window Spacer may be cut to fit If window spacer does not fill opening completely a custom made spacer from...

Page 6: ...on NOTE For best results do not exceed a 45º angle Fig 10 The hose may be extended from 1 5 ft 300mm 1500mm but for maximum efficiency use the shortest straightest length possible It is not recommended to exceed 5 feet for this will diminish the efficiency of the unit See WARNING Figure 11 6 WARNING The length of the exhaust pipe is specially designed according to the specification of this product...

Page 7: ...eassembling the fixer to the filter frame 6 Re fit the filter frame inside the unit 7 1 Power indicator 2 Fan operating indicator 3 Cooling operating indicator 4 Full water indicator 5 Heating operating indicator ARP 1200DM only 6 Timer 1 8 hours as well as ON OFF Switch 7 Speed switch with options for FAN LOW COOL HIGH COOL LOW HEAT HIGH HEAT 8 Thermostat OPERATION for mechanical unit ARP 1200M A...

Page 8: ...et time has been reached the machine will shut off automatically NOTE 1 To lengthen the compressor s life when the unit is turned off wait at least 3 minutes before turning it back on 2 The cooling system will turn off if the ambient temperature is lower than the set one The ventilation however keeps working on the set level If the ambient temperature rises above the selected level the cooling fun...

Page 9: ...will be lit Auto mode is factory preset at 75 degrees When in auto mode auto and cool light illuminated the temp up and temp down buttons are disabled and you cannot set a desired temperature If you want a desired temperature above or below 75 run unit in cool mode and set your desired temperature by pressing the temp up or temp down buttons OPERATION for electronic unit Control panel 1 Heating op...

Page 10: ... operating hours desired 1 to 12 hours the timer indicator will light on When the set time has been reached the machine will turn off automatically The display window will show the hour s you set as you press the TIMER button If the timer button is not pressed the unit will work continuously 2 By pressing the timer but without turning on the other functions you can PRESET the time for the machine ...

Page 11: ...uring high humidity levels excess water may fill the internal water tray Depending on how high the humidity and the duration of high humidity levels will depend on how often the unit needs to be drained When the reservoir full a For the mechanical model the compressor will stop only the fan ill continue to circulate the air The FULL WATER indicator will light up b For the electronic model both of ...

Page 12: ...xtend the water tube you can connect it with another tube OD 7 18mm Caution for heating function While using the heating function please note 1 In heat mode the exhaust MUST be exhausted to the outside just as in air conditioning mode The unit works in reverse of air conditioning mode with the warm air out the front and cold air is exhausted out the back 2 Fix the drainage to be a continuous one i...

Page 13: ...a vacuum cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under running water no hotter than 104o F 40 o C Dry thoroughly before replacing NOTE Never operate the unit without the filters End of season storage Drain any water from the unit Operate the unit in fan mode only for a few hours to thoroughly dry the inside Clean or change the filter Unplug and store t...

Page 14: ...floor underneath the machine uneven Is the filter dusty or contaminated Is the air intake or output blocked up Is the room temperature below your selected temperature Is there direct light Please pull down the curtain Are too many windows or doors open Are there too many people in the room Is there something in the room producing heat Is the air conditioner plugged in Reset plug breaker by pressin...

Page 15: ... A 930 W 8 6 A Refrigerant R22 Control manual manual electronic w remote electronic w remote Carton weight 73 lbs 33 kg Carton Dimension W x H x D 19 7 x 15 7 x 29 5 in 500 x 400 x 750 mm Noise Level 54 1 dB A NOTE 1 Heating capacity is only for the models with the heating function i e model no ARP 1200 DM ARP 1200 DE 2 Measuring condition for above is Cooling RT 80 6 F 27 o C RH60 Heating RT 68 F...

Page 16: ... our factory or service center If shipping is required be sure to pack the unit properly to avoid shipping damages as we will not be responsible for such damages THIS WARRANTY IS VALID THROUGHOUT THE UNITED STATES AND PUERTO RICO ONLY EXCLUSIONS This warranty excludes and does not cover defects malfunctions or failures of your Royal Sovereign Portable Air Conditioner caused by repairs by unauthori...

Page 17: ...0DM ARP 1200E ARP 1200DE MANUAL DEL PROPIETARIO ACONDICIONADOR DE AIRE PORTÁTIL Lea y conserve estas instrucciones para referencia futura Para preguntas por favor Visite nuestra pagina de internet www royalsovereign com service al cliente ...

Page 18: ...AIRE CONDICIONADO PORTABLE Model ARP 1200M ARP 1200DM ARP 1200E ARP 1200DE ...

Page 19: ...MBIENTES HÚMEDOS FIG 3 NO ARRASTRE LA UNIDAD TIRANDO DEL CORDÓN DE ALIMENTACIÓN ELÉCTRICA SI EL CORDÓN DE ALIMENTACIÓN ELÉCTRICA ESTÁ DAÑADO DEBE REEMPLAZARLO UN ELECTRICISTA COMPETENTE PARA EVITAR RIESGOS O LESIONES PARA LOGRAR EL RENDIMIENTO MÁXIMO No exceda el tamaño recomendado de la habitación 164 pies cúbicos 50m3 normalmente 66 pies cuadrados 20m2 de área útil Cierre puertas y ventanas Mant...

Page 20: ...e disyuntor LCDI y botones de 9 Tapón para el agua punto de drenaje COMPONENTES Accesorios 10 Adaptador de acondicionador para conectar a la manguera y a la parte posterior del acondicionador 11 Adaptador de ventana para insertar sobre la manguera y en el espaciador de ventana 12 Manguera de descarga 13 Espaciador de ventana extensible 14 Tubo de drenaje para drenaje continuo 15 Bandeja para el ag...

Page 21: ... manguera de descarga al adaptador exterior 3 Inserte el espaciador de ventana en las aberturas de la ventana como se muestra en la ilustración Ajuste la longitud si es necesario 4 Deslice la ventana sobre el espaciador para que éste se fije firmemente NOTA Instalar el respiradero verticalmente o horlzontalmente dependiendo del estilo de ventana El espaciador de la ventana se puede cortar a la med...

Page 22: ...ras 8 y 9 muestran la posición correcta NOTA Para mejores resultados no exceda 45 grados de angulo La manguera puede extenderse de 1 a 5 pies 300 a 1500 mm pero para lograr el máximo rendimiento useel tramo recto más corto posible No se recomienda usar más de 5 pies 1500 mm ya que esto disminuirá la eficiencia de la unidad Vea la ADVERTENCIA de la Fig 11 22 ADVERTENCIA El tubo de descarga tiene un...

Page 23: ...ad 23 1 Indicador de alimentación eléctrica 2 Indicador de funcionamiento de la ventilación 3 Indicador de funcionamiento de la refrigeración 4 Indicador de Bandeja de agua llena 5 Indicador de funcionamiento de la calefacción sólo para modelos ARP 1200DM 6 Temporizador 1 8 horas y llave de encendido apagado ON OFF 7 Llave de velocidades con opciones para VENTILACIÓN REFRIGERACIÓN BAJA REFRIGERACI...

Page 24: ...uste del temporizador Ajuste el TEMPORIZADOR TIMER al tiempo de funcionamiento deseado 1 a 8 horas Cuando transcurre el tiempo fijado la unidad se apaga automáticamente ATENCIÓN 1 Cuando apague la unidad espere por lo menos 3 minutos antes de volver a encenderla para prolongar a vida útil del compresor 2 Cuando la temperatura ambiente es más baja que el valor fijado la función refrigeración se apa...

Page 25: ...l modo automático está prefijado en fábrica a 75 F 24 C Cuando está en este modo luz de automático y enfriamiento encendidas están desactivados los botones de aumento y bajada de temperatura y no se puede fijar una temperatura deseada Si desea una temperatura por encima o por debajo de 75 F 24 C haga funcionar la unidad en el modo de enfriamiento y fije la temperatura deseada oprimiendo los botone...

Page 26: ...IZADOR TIMER para seleccionar el tiempo de funcionamiento deseado 1 a 12 horas el indicador del temporizador se ilumina Una vez transcurrido el tiempo seleccionado la unidad se apaga automáticamente El indicador visual muestra la hora s seleccionada s al oprimir el botón TEMPORIZADOR Si el botón temporizador no se oprime la unidad seguirá funcionando continuamente 2 Si oprime el temporizador sin a...

Page 27: ...ción DRENAJE Durante el proceso de refrigeración la unidad absorbe humedad del ambiente que se condensa en su interior como agua Cuando el depósito se llena de agua a En el modelo mecánico el compresor se detiene y sólo el ventilador continuará haciendo circular el aire El indicador BANDEJA DE AGUA LLENA FULL WATER se ilumina b En el modelo electrónico se detienen el compresor y el motor La luz de...

Page 28: ... diámetro exterior 7 18mm Precaución especial con la función calefacción Al usar la función calefacción tenga en cuenta 1 En el modo de calefacción la descarga debe hacerse al exterior como en el modo de aire acondicionado La unidad funciona a la inversa del acondicionamiento de aire con la descarga de agua caliente por la parte delantera y la de aire frío por la parte trasera 2 Asegúrese que el d...

Page 29: ...n grifo para quitar el polvo y la suciedad luego enjuague con agua corriente a temperatura no superior a los 40 o C Seque el filtro completamente antes de volver a colocarlo ATENCI Nunca opere la unidad sin los filtros Al finalizar la temporada de almacenamiento Drene de la unidad el agua residual Opere la unidad sólo en modo ventilación durante unas pocas horas para lograr un secado total del int...

Page 30: ... El indicador comp bandeja de agua llena parpadea La temperatura ambiente está por debajo del valor fijado Hay luz diurna directa Baje las cortinas Hay demasiadas ventanas o puertas abiertas Hay demasiadas personas en la habitación Hay algo en la habitación que genere calor El filtro tiene mucho polvo o está contaminado La entrada salida de aire está bloqueada La temperatura ambiente está por deba...

Page 31: ...6 A Control Manual Electronic w remote Refrigerante R22 Peso neto 73 lbs 33 kg Dimensiones 19 7 x 15 7 x 29 5 pulgadas 500 x 400 x 750 mm Nivel de ruido 54 1 dB A NOTA 1 La capacidad de calefacción se refiere solamente a los modelos que poseen dicha función o sea los modelos Nº ARP 1200DM y ARP 1200DE 2 Las condiciones de medición para los datos anteriores son las siguientes Refrigeración Temperat...

Page 32: ...la unidad sea entregada en nuestra fábrica o centro de atención al cliente corresponden al comprador Para despachar la unidad la misma debe embalarse adecuadamente para evitar daños durante el transporte ya que Royal Sovereign no asume responsabilidad por tales daños ESTA GARANTÍA TIENE VALIDEZ SOLAMENTE PARA EE UU Y PUERTO RICO EXCEPCIONES La garantía excluye y no cubre defectos funcionamiento de...

Reviews: