JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 34 of 48
SCAN TRACEABILITY
BARCODE 1
Press START if done.
You can scan one (1) or more traceability barcodes at this time, up to six (6) barcodes. When you scan
multiple barcodes, the display will update accordingly to indicate the number of barcodes scanned.
THE OPERATOR MUST SCAN AT LEAST ONE (1) TRACEABILITY BARCODE UNLESS THE PIPE/FITTING OPTION IS
SET TO “
OPT
” (OPTIONAL).
When you are finished scanning traceability barcodes, or if you do not wish to scan any traceability barcodes
during this fusion, press the
START button
to advance to the VERIFY SETUP screen. Alternately, if the
maximum number of traceability barcodes (6) has been scanned, the processor will automatically advance to
the VERIFY SETUP screen.
FOR DATA INTEGRITY REASONS, THERE IS NO METHOD TO MANUALLY INPUT TRACEABILITY DATA.
Operator ID
The Operator ID codes are an option that can only be enabled through the Advanced User Menu (see page
28), When enabled, Operator ID codes can be entered in two ways:
•
“O
N
” requires
the operator to manually enter an Operator ID code before a fusion may proceed.
•
“S
CAN
”
requires an operator to scan an ISO 12176-3 compliant Operator ID badge before a fusion may
proceed. Contact an authorized representative (See page 15) to find out more about generating this
badge.
If the Operator ID codes are enabled, the following screen will be displayed after the processor has passed its
INTERNAL SELF TEST:
TRACEABILITY
Operator:
Operator ID codes entered here will be attached to all fusions performed by this processor until the power is
turned off or the Operator ID code is changed. This Operator ID data will not affect the fusion but will be
associated with each fusion in the download.
If the Operator ID function is set to “ON”, manually enter the desired Operator ID code.
See page 33 for
details on how to enter data with the keypad
. Manually entered Operator ID codes may contain up to 10
characters and include letters and/or numbers. When the
START button
is pressed after the last character,
the processor will advance to the CONNECT FITTING screen. See page 19 for details on how to perform a
fusion.
If the Operator ID function is set to “SCAN”, use a barcode wand or SMART Scanner™ to scan the desired
Operator ID barcode. Press the
START button
to accept the scanned Operator ID and advance to the
CONNECT FITTING screen. See page 19 for details on how to perform a fusion.