4. Run the fluid through meter into a graduated container until the Test Volume has been reached
(e.g., 100). Press the MODE button to stop the test.
5. The unit will now compare the Measured Volume to the Test Volume
and perform an Auto Calibration if the difference between the two
volumes are within ± 8 % of each other.
Returning to Operation Mode
At any stage during the programming, the meter can be returned to the operation mode by pressing
the RESET button for approximately 5 seconds.
Operating Instructions
1. Press the reset button before starting the operation.
2. Pull the trigger to dispense oil and release it to stop dispensing. While dispensing, the display
shows the amount of oil dispensed since the last reset.
After Each Use
•
Make sure the meter is stored in a dry and secure area to extend the meter life.
Maintenance
⚠
WARNING
•
Always make sure the liquid has been drained from the meter and the line pressure is released
before cleaning.
The meter has been designed to require minimum maintenance but the battery will need to be
changed and the meter body will need to be cleaned.
Summary of Contents for 67151