background image

Page 6 of 16 

 

CAUTION

 

DIGITAL OIL METER USE AND CARE 

 

Do not force the digital oil meter. Products are safer and do a better job when used in the manner 

for which they are designed. Plan your work, and use the correct product for the job. 

 

Check for damaged parts before each use. Carefully check that the product will operate properly 

and perform its intended function. Replace damaged or worn parts immediately. Never operate the 

product with a damaged part. 

 

Do not use a product with a malfunctioning switch. Any power tool that cannot be controlled with 

the power switch is dangerous and must be repaired by an authorized service representative 

before using. 

 

Disconnect the power/air supply from the product and place the switch in the locked or off position 

before making any adjustments, changing accessories, or storing the tool. Such preventive safety 

measures reduce the risk of starting the tool accidentally. 

 

Store the product when it is not in use. Store it in a dry, secure place out of the reach of children. 

Inspect the tool for good working condition prior to storage and before re-use. 

 

Use only accessories that are recommended by the manufacturer for use with your product. 

Accessories that may be suitable for one product may create a risk of injury when used with 

another tool. Never use an accessory that has a lower operating speed or operating pressure than 

the tool itself.

 

Specific Operation Warnings 

WARNING

 

 

Do not exceed the maximum working pressure of 1000 PSI. 

 

Always filter the fluid by installing a filtering element on the meter inlet. If solid particles enter the 

measuring chamber, the correct working of the oval gears may be affected. 

 

If using in an inline application, open the inlet valve slowly to prevent over spinning the gears.

 

 

Do not use with water-based media or gasoline.

 

Main Parts of Product 

 

Summary of Contents for 67151

Page 1: ...il Meter Owner s Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result...

Page 2: ...at you read the entire manual to become familiar with this product before you begin using it This digital oil meter is designed for certain applications only Northern Tool and Equipment is not respons...

Page 3: ...ions 4 Important Safety Information 4 Specific Operation Warnings 6 Main Parts of Product 6 Installation Instructions 7 Before Each Use 7 Operating Instructions 10 After Each Use 10 Maintenance 10 Tro...

Page 4: ...9 units Max Non Resettable Totalizer 999999 units Least Count Resolution 0 0010 unit Filter Screen Included No Max Viscosity of Media SAE 140 1000 CP Option to Recalibrate by User Yes Protective Shro...

Page 5: ...resence of flammable liquids gases or dust The product can create sparks which may ignite the flammable liquids gases or dust Keep children and bystanders away from the work area while operating the t...

Page 6: ...storing the tool Such preventive safety measures reduce the risk of starting the tool accidentally Store the product when it is not in use Store it in a dry secure place out of the reach of children I...

Page 7: ...move the rubber shroud 1 Unscrew the four screws 2 with a Phillips head screwdriver in a diagonal sequence and separate the electronic module 3 from the meter body 5 2 Rotate the electronic module 3 i...

Page 8: ...f decimal places currently set on the main display 3 Press the MODE button to cycle through options available dEC 1 1 decimal place dEC 22 2 decimal places dEC 333 3 decimal places Configuring Units 1...

Page 9: ...Meter 1 The LCD will display CALIBRATE in the lower left hand corner as well as a number on the main display This represents the Test Volume to be dispensed through the meter during calibration 1 Pre...

Page 10: ...ng the RESET button for approximately 5 seconds Operating Instructions 1 Press the reset button before starting the operation 2 Pull the trigger to dispense oil and release it to stop dispensing While...

Page 11: ...al gears 6 4 Clean the meter body 5 with a soft brush or cloth Be careful not to damage the meter body or the gears 5 Assemble in the reverse order taking care of the following Position the oval gears...

Page 12: ...eaning the Meter Body Meter connections are over tightened Re adjust connections Fluid is too thick Use fluid of specified viscosity up to SAE 140 Insufficient accuracy Fluid flow rate is too high or...

Page 13: ...Page 13 of 16 Parts Diagram...

Page 14: ...Customer Service at 1 800 222 5381 Not all product components are available for replacement The illustrations provided are a convenient reference to the location and position of parts in the assembly...

Page 15: ...claim contact Us at 1 800 222 5381 identify the product by make and model number and follow the claim instructions that will be provided The product and the purchase receipt must be provided to Us in...

Page 16: ...Page 16 of 16 Distributed by Northern Tool Equipment Company Inc Burnsville Minnesota 55306 www northerntool com Made in India...

Reviews: