Page 5 of 16
Air and fluid hoses:
Make sure they are effectively grounded.
Air compressor:
Follow the manufacturer's instruction to ground it.
Control valve:
Use proper grounding wire to connect it to the pump. Always keep the metal part of the
control valve connected with the grounding equipment.
Oil Barrel:
Use a barrel that can meet the local standard and ground it properly. A metal barrel can be
put directly on a surface of an electrical conductor that is properly grounded.
Other components:
Ensure all parts are properly grounded to avoid risk of electrical shock.
WARNING:
Always keep effective grounding when working or releasing pressure.
NOTE:
Use oil resistant pipe sealant or Teflon
®
Tape on all fitting threads.
1. INSTALLATION OF OIL PUMP KIT
①
. Secure the bracket (part# 4 of oil pump kit) to the wall using the dowels (NOT INCLUDED) at a height
appropriate for the tank’s dimension. Make sure that the wall is solid and thick enough for the dowels. Do
not interfere with hydraulic tubes or electric lines.
②
. Secure the pump (part# 1 of oil pump kit) to the bracket (part# 4 of oil pump kit).
③
. Connect the flexible suction tube (part# 6 of oil pump kit) to the pump using the clamp provided.
. Connect the rigid suction (part# 8 of oil pump kit) to the other end of the flexible suction tube (part# 6 of oil
pump kit) using the elastic clamp provided.
. Put the bung adapter (part# 7 of oil pump kit) into the drum hole.
. Put the rigid suction tube (part# 8 of oil pump kit) into the pump and secure it in place.
. Connect the pump to the hose reel with the 13ft. connection hose.
. Install the air filter and regulator to the air inlet of the pump with the adapter attached.
. Make sure the air supply valve is closed before connecting the air supply line with air filter and regulator.
2. INSTALLATION OF HOSE REEL
WARNING:
Before mounting the hose reel, ensure that the supply line pressure does not exceed the
maximum working pressure of the hose reel.
Unpack and inspect reel for damage. Turn by hand to check for smooth operation. Check for completeness.
Position the reel on the floor, wall or ceiling. Secure into place using four mounting bolts (NOT INCLUDED).
See Fig. 2.
NOTE:
Depending on where the reel is placed, it may be necessary to adjust the hose bumper and guide arm
to use the hose properly. See the instructions on the next page to adjust the hose bumper and reposition the
guide arm.
Fig.1 Ground the pump
1. Ground Screw
2. Ground Wire