INSTALLATION
Typical installation refers to Fig.1.
Fig. 1
NOTE:
The above typical installation is only for reference. It may be different from your actual system design.
WARNING:
If this is a new installation, or if the oil in the lines is contaminated, flush the lines before you
install the kit. No impurities or contaminant are allowed to enter the kit.
WARNING:
To reduce the risk of serious injury, the pressure release should be concerned. Please
follow the
Pressure Relief Procedure
in
OPERATION INSTRUCTIONS
section for the release process.
WARNING:
Before operating the pump, check the grounding of whole system to avoid the risk of fire and
explosion.
To reduce the risk of static sparking, effectively ground all of this equipment.
Pump:
Refer to Fig.1. Use ground wire and clamp as shown in Fig. 1. Remove the ground screw 1.
Connect the ground wire 2 to a true earth ground by inserting the terminal end of ground wire 2 through
the eye of the ring. Fasten the ground screw 1 back onto the pump and tighten securely.