Page 2: ...2 1 On Off 4 2 2 Zero 4 2 3 Change units 5 3 Before usi ng the meter for the first time 5 4 Before using the meter every time 5 5 Unit options 6 6 Measuring 7 8 Specification 8 9 Electromagnetic compatibility 9 10 Cold weather precautions 10 11 End of life disposal 10 ...

Page 3: ...egments are oper ated and 3200 appears on the display The display will then show the following sequence 1 0 the firmware version HPA the units currently set ZERO the zeroing sequence 04 03 02 01 00 00 0 the measured value The meter is now ready to use To switch OFF press and hold until OFF appears on the display During this period the meter will display the units currently set Press and hold until...

Page 4: ...ment Take great care to ensure that the battery is fitted with the correct battery polarity Then replace the battery cover Always check that the meter is working correctly after replacing the battery Warning Never connect to a pressure source where you are not sure what the maximum pressure might be Always ensure that the meter you are using is correctly rated for the pressure that you intend to m...

Page 5: ...ENGLISH 5 5 Unit options PS UNITS User selectable units are mBAR inH20 hPa mmHg PSI kPa Pa mmH2O These are displayed as follows kPa PSI mmHg hPa inH2O mBar mmH20 Pa ...

Page 6: ...g single channel measurements pressure or vacuum Only use the left hand port for differential measurements If the pressure being measured exceeds the meter s design range the display will show for over range When taking draft readings at very low pressure or draft levels for maximum accuracy re zero the meter in the orientation that it is being used This eliminated gravity effects on the very sens...

Page 7: ... reading whichever is greater Maxi mum over range without damaging the sensor is 1000 mbar BATTERY LIFE Greater than 250 hours continuous operation with a 9 V PP3 alkaline battery AMBIENT TEMPERATURE RANGE 0oC to 50oC AMBIENT HUMIDITY 10 RH to 90 RH non condensing DIMENSIONS Weight 295 grams with battery Handset 160mm x 80mm x 40mm 180mm including spigots Scale Range Highest resolution Mbar 200 0 ...

Page 8: ...in the location where the meter will be used Switch on all localized electrical equipment capable of causing interference Check all reading are as expected A level of disturbance is acceptable If not acceptable adjust the meter s position to minimize interference or switch off if possible the offending equipment during your test At the time of writing this manual April 2016 Kane International Ltd ...

Page 9: ...or water ingress it may be possible to rectify the problem yourself Simple leave the product running in a warm place for a few hours use mains adapter battery charger if needed If after doing this you still experience problems please contact our Customer Service centres The Waste Electrical or Electronic Equipment WEEE Directive requires countries in the EU to maximise collection and environrmenta...

Page 10: ...IN THE MANUAL Register your RO 3200 to create your KAM dashboard Simple online booking on www kane co uk Automatic reminder when due for recertification FREE POSTAGE returning your Rothenberger analyser SAME DAY annual FGA recertification OR YOUR MONEY BACK Register your RO 3200 4 ...

Page 11: ... 65779 Kelkheim Germany Telefon 49 6195 800 0 Telefax 49 6195 800 3500 info rothenberger com ROTHENBERGER UK LIMITED 2 Kingsthorne Park Henson Way Kettering Northants NN16 8PX Tel 44 0 1536 310300 Fax 44 0 1536 310600 E info rothenberger co uk rothenberger com ...

Reviews: