4 Installation
Installation manual
6
RRLQ004~008CAV3
ROTEX HPSU low temperature Bi‑bloc
4PW74444-1D – 2018.07
NOTICE
If the drain holes of the outdoor unit are blocked up,
provide space of at least 300 mm below the outdoor unit.
An additional drain pan kit (EKDP008CA) can be used to gather the
drain water. The drain pan kit consists of:
b
a
a
Drain pan
b
U-beams
283 mm
580 mm
INFORMATION
If you install the drain pan kit (with or without drain pan
heater) in combination with the low sound cover
(EKLN08A1), different installation instructions apply for the
drain pan kit. See the installation manual of the low sound
cover.
a
b
d
c
c
b
a
Low sound cover
b
Bottom parts of the low sound cover
c
Drain pan kit
d
Drain pan heater
4.2.4
To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit
to prevent the cables from scratching the paint (field supply).
4
Attach the ends of the cables and tighten them.
4.3
Connecting the refrigerant piping
DANGER: RISK OF BURNING