Installation manual
3
RKHBRD011~Y1
Indoor unit for air to water heat pump system
4PW61218-1C – 2012.06
The remote controller gives immediate feedback to the indoor
unit and by doing so it matches in a smart way the unit
performance to the demanded space heating requirements. In
this way there is no frequent start/stop of the unit or there are no
too big temperature fluctuations in the to be heated rooms. This
remote controller has also a smart logic functionality which
controls the combined space heating and domestic hot water
demand (e.g. if room temperature drops more than 3°C during
domestic hot water operation, the unit will automatically switch
back to space heating). There is no remote controller near the
unit. During service maintenance an additional remote controller
can be connected by a service person.
■
Application 2
Space heating and domestic hot water heating with one remote
controller installed with the unit, and another remote controller
installed in the living room.
The remote controller gives immediate feedback to the indoor
unit and by doing so it matches in a smart way the unit
performance to the demanded space heating requirements. In
this way there is no frequent start/stop of the unit or there are no
too big temperature fluctuations in the to be heated rooms. This
remote controller has also a smart logic functionality which
controls the combined space heating and domestic hot water
demand (e.g. if room temperature drops more than 3°C during
domestic hot water operation, the unit will automatically switch
back to space heating). The main remote controller (C1) is
installed in the living room and can access all settings (master).
The second remote controller (C2) can not access schedule and
field settings (slave).
Refer to the chapter "Electrical wiring work" on page 15 about
connecting the master and slave remote controller.
■
Application 3
Space heating and domestic hot water heating with a single
remote controller installed with the unit, and the external room
thermostat installed in the living room.
There is only a room thermostat on/off control. There is no smart
logic functionality for space heating. When there is simultaneous
demand of space heating and domestic hot water, the domestic
hot water operation is performed according to the minimum and
maximum timer operation.
1
Outdoor unit
10
Collector (field supply)
2
Indoor unit
11
Radiator (field supply)
3
Refrigerant heat
exchanger
12
Electronic expansion
valve
4
Water heat exchanger
13
By-pass valve (field
supply)
5
Compressor
6
Pump
C1
Remote controller
(master)
7
Shut-off valve
8
Motorized 3-way valve
(optional)
C2
Optional remote
controller (slave)
9
Domestic hot water
tank (optional)
A
Installation place
B
Living room
10 13
C1
A
B
C2
7
4
3
12
12
2
1
8
6
5
M
11
9
Master
Slave
Operation ON/OFF
Operable
Operable
Domestic water heating operation ON/OFF
Operable
Operable
Setting the leaving water temperature
Operable
Operable
Setting the room temperature
Operable
Operable
Quiet mode ON/OFF
Operable
Operable
Weather dependent set point operation
ON/OFF
Operable
Operable
Setting the clock
Operable
Operable
Programming the schedule timer
Operable
—
Schedule timer operation ON/OFF
Operable
—
Field settings
Operable
—
Error code display
Operable
Operable
Test operation
Operable
Operable
Room thermostat functionality
Operable
—
Optionally the Rotex room thermostat RKRTR or
RKRTW can be connected to the Rotex system.
Rotex can not guarantee neither good operation nor
reliability of the system if another thermostat is used.
For those reasons Rotex can not give warranty of the
system in such case.
1
Outdoor unit
10
Collector (field supply)
2
Indoor unit
11
Radiator (field supply)
3
Refrigerant heat
exchanger
12
Electronic expansion
valve
4
Water heat exchanger
13
By-pass valve (field
supply)
5
Compressor
6
Pump
C1
Remote controller
7
Shut-off valve
T
Room thermostat
8
Motorized 3-way valve
(optional)
A
Installation place
B
Living room
9
Domestic hot water
tank (optional)
C1
7
4
3
12
12
2
1
8
6
5
M
11
9
10 13
T
A
B