3 Operation

Operation manual

3

RHBH/X04~16CB
ROTEX HPSU low temperature Bi‑bloc
4P384967-1B – 2017.04

e

User interface in the living room, used as room thermostat

f

Underfloor heating

g

Heat pump convectors or fan coil units

INFORMATION

The  indoor  unit  and  the  domestic  hot  water  tank  (if
installed) can be separated or integrated depending on the
indoor unit type.

3

Operation

3.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating/cooling
control

How to control space heating/cooling:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches between home pages (when you are on a home

page).

▪ Goes to the default home page (when you are in the menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages.
Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens  the  menu  structure  (when  you  are  on  a  home

page).

▪ Goes  up  a  level  (when  you  are  navigating  through  the

menu structure).

▪ Goes back 1 step (example: when you are programming a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or

between  displaying  actual  and  offset  values  (if  applicable)
on the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

▪ Enables you to activate or deactivate button lock if pressed

for more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed for more than 5 seconds in the main menu of the
menu structure.

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Button lock mode and/or function lock mode is active.

Summary of Contents for RHBH04CB

Page 1: ...Operation manual ROTEX HPSU low temperature Bi bloc English Operation manual ROTEX HPSU low temperature Bi bloc RHBH04CB RHBH08CB RHBH11CB RHBH16CB RHBX04CB RHBX08CB RHBX11CB RHBX16CB ...

Page 2: ... used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read before operating your system Format Paper in the box of t...

Page 3: ...are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between displaying actual and offset values if applicable on the home pages Goes to the next ...

Page 4: ...pending on installer settings also the indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switched the permission level to Advanced end user Prerequisite You switched the space operation mode to automatic 1 Go to 7 5 User settings Allowed operation mode ...

Page 5: ... 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in scheduled mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats up until it reaches the reheat set point example 45 C Th...

Page 6: ...hedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and to select ...

Page 7: ... metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater permis...

Page 8: ...and long space heating cooling interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank booster mode is active the risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long ...

Page 9: ...he contact helpdesk number Prerequisite You switched the permission level to Advanced end user 1 Go to 6 3 2 Information Error handling Contact helpdesk number 6 Troubleshooting 6 1 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one o...

Page 10: ...e occurs the domestic hot water and space heating operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the backup heater or booster heater can take over the heat load or not When the heat pump fails will appear on the user interface Possible cause Corrective action Heat pump is damaged Press to view a description of the problem Press again ...

Page 11: ......

Page 12: ...land Our partners abroad Unsere Partner im Ausland Nos partenaires à l étranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granicą Naši partneři v zahraničí http de rotex heating com ueber rotex international 4P384967 1B 2017 04 ROTEX Subject to change and correction ...

Reviews: