3 Operation

Operation manual

4

R2CND0 R2TND012~024A4AA

Wall-mounted condensing boiler

3P469438-4D – 2017.07

3.1.1

Buttons and dials

The  three  buttons  and  two  dials  on  the  user  interface  have  various
functions  according  to  different  situations,  which  are  stated  in  the
table below:

Button/Dial

Function

Description

Mode /
Reset

Mode

Change mode between summer,
winter, central heating only, standby
and full-off.

Reset

Reset the lockout error.

Cancel /
Back

Cancel

Cancel changes.

Back

Go back to the parent menu.

Menu / Enter Menu

Enter the menu function.

Enter

Passing on to the next level in the
menu structure.

Confirm

Confirmation of changes.

Left dial

User
interaction
level

Central heating temperature setpoint.

This is either the central heating flow
temperature, the room temperature,
or the virtual room temperature,
depending on the system
configuration.

Menu level

Selection of info, user, service menu.

Right dial

User
interaction
level

Domestic hot water temperature
setpoint.

Menu level

▪ Selection parameter index.

▪ Change parameter values.

3.1.2

LCD screen

LCD  screen  is  the  monitor  of  the  user  interface.  You  can  see  the
boiler  operation  mode,  setpoints,  information  about  actuators  and
menu parameters on this screen.

The  LCD  screen  has  a  sleeping  function.  After  one  minute  of  non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.

When you interact with the user interface, the LCD screen will show
the  home  screen  of  the  active  operation  mode  and  the  related
setpoint, depending on the system configuration (see 

"3.3.3 Possible

operation modes" on page 5

).

Status icons

Meaning of icons that appear on the LCD screen:

Icon

Description

Operation mode: Standby mode

Domestic hot water operation enabled

Domestic hot water comfort mode is enabled

Central heating operation enabled

Room temperature

Outdoor sensor connection

Central heating ECO mode enabled

Network connection

Info menu

User settings menu

Service settings menu

3.1.3

Status indicator

The status indicator gives first level feedback on the operation mode
and status of the boiler.

Status

Description

Standby

When there is no heat demand, the status
indicator shows this with a kind of breathing
pulsation of the blue and white LED.

Flame

At the moment flame ignites for central heating or
domestic hot water, the ring flashes to its
maximum, then constantly keeps glowing during
burner operation.

Error

The status indicator will go into error mode when a
warning, lockout or blocking error occurs (see

"3.4 Error handling" on page 7

). During the error

condition the status indicator continuously shows
the red blinking LED.

NOTICE

In  warning  error,  the  status  indicator  colour  turns  to  blue
while the boiler is operating.

3.2

Operating the unit

3.2.1

To switch ON the unit

1

Connect the unit to the main power supply.

2

Press the "Mode" button for 5 seconds to switch ON the unit.

3

After  that,  you  can  select  an  operation  mode  by  pressing  the
"Mode" button shortly.

Use of the unit is explained in following parts of this manual.

3.2.2

About the low water temperature function

The  low  water  temperature  function  is  a  safety  function  that  takes
place  at  first  central  heating  operation  after  each  power  supply
interruption and at first central heating operation after each 90 days.
When  this  function  is  active,  boiler  operates  according  to  a  defined
set  value  for  around  15  minutes  and  the 

  icon  blinks.  After  this

function is ended, normal operation goes on.

INFORMATION

Low  water  temperature  function  is  a  safety  function  and  it
cannot be disabled.

3.2.3

About the electronic gas adaptive system
calibration

The  electronic  gas  adaptive  system  calibrates  itself  in  pre-
determined time intervals. First calibration takes place just after first
burner activation after each power ON. Calibration process duration
is  around  60  seconds  and  the 

  icon  blinks.  After  calibration  is

ended,  boiler  modulates  to  required  capacity.  Calibration  process
has no effect on boiler operation.

3.3

Basic usage

3.3.1

About the home screen

It is the screen that is displayed after activating the LCD screen with
one of the dials or buttons. You can use the home screen to read out
settings that are meant for daily use. What you can see on the home
screen depends on your system configuration.

The following home screens may be possible:

▪ Room temperature (ROTEX room thermostat connected)

▪ Central heating set temperature

Summary of Contents for R2CND-A4A

Page 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler R2CND024A4AA R2TND012A4AA R2TND018A4AA R2TND024A4AA ...

Page 2: ...pply Filling loop R2CND024A4AA R2CND024 Instantaneous External R2TND012A4AA R2TND012 Storage tank External Model Type Domestic hot water supply Filling loop R2TND018A4AA R2TND018 Storage tank External R2TND024A4AA R2TND024 Storage tank External A control unit which contains a user interface controls the ignition safety systems and other actuators User interaction is provided via that user interfac...

Page 3: ...Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modifications on Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is able to be operated with both natural gas and LPG The pr...

Page 4: ...iler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central heating or domestic hot water the ring flashes to its maximum then constantly keeps glowing during burner operation Error The status indicator will go into error mode when a warning lockout or blockin...

Page 5: ...ter operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well as produce heat for central heating The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes on page 6 and...

Page 6: ...ial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating operation mode is enabled NOTICE To enable weather compensation the heating slope value must be higher than 5 see User settings menu Parameters short on page 8 INFORMATION If an outdoor sensor is connected...

Page 7: ...ing When an error occurs the normal behaviour of the user interface is interrupted and the status of the status indicator is affected However be aware that not all errors have the same effect on the user interface and the status indicator Error type Boiler operation User interface and status indicator Warning Continue The status indicator does not enter error mode if the burner is on It turns to r...

Page 8: ...dependency 1 1 2 or 24 U10 Room temperature setpoint used by ROTEX Opentherm room thermostat during night C 18 10 30 User settings menu Parameters detailed Description U00 When using outdoor sensor above this parameter value of outside temperature the boiler senses the season as summer and does not activate central heating although there is demand Summer winter switching has a hysteresis of 1ºC i ...

Page 9: ...of your boiler with a damp cloth and a little solvent free soap CAUTION Sprays solvents or cleaning agents containing chlorine can damage the exterior the fittings or the control unit Do not use them for cleaning purposes 5 Energy saving tips Operating the unit in central heating ECO mode provides the most economical central heating operation conditions Do not run the boiler in domestic hot water ...

Page 10: ...eded If problem repeats contact your service agent E1 66 Calibration conditions fault No reset needed Wait burner to restart If problem repeats contact your service agent E1 67 Missing calibration Perform reset If problem repeats contact your service agent Problem Solution E1 68 Ion base value is outside the factory limits or saved incorrectly Perform reset If problem repeats contact your service ...

Page 11: ...Solution UA 66 BCC ID of internal EEPROM is inconsistent Contact your service agent UA 67 BCC is missing Contact your service agent UA 68 BCC is not compatible with PCB BCC ID Contact your service agent UA 69 BCC is not compatible with PCB firmware Contact your service agent UA 70 BCC update error Contact your service agent ...

Page 12: ...land Our partners abroad Unsere Partner im Ausland Nos partenaires à l étranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granicą Naši partneři v zahraničí http de rotex heating com ueber rotex international 3P469438 4D 2017 07 ROTEX Subject to change and correction ...