![Rotex GCU compact 315 Installation And Maintenance Instructions Manual Download Page 57](http://html1.mh-extra.com/html/rotex/gcu-compact-315/gcu-compact-315_installation-and-maintenance-instructions-manual_1491090057.webp)
8
x
Hydraulic connection
8 Hydraulic connection
8.1 Hydraulic system connection
WARNING!
To prevent flue gas from escaping, the storage tank must be
filled to overflow when starting up the ROTEX GCU compact.
WARNING!
High temperatures can occur in the solar storage tank.
Therefore, sufficient scalding protection must be included when
the hot water system is installed (automatic hot water mixing
device).
CAUTION!
The ROTEX units can also be optionally fitted with gravity
breaks (
16 50 70
) made of plastic. They are suitable for
maximum operating temperatures of 95 °C. If a heat exchanger
is operated at temperatures greater than 95 °C, another gravity
brake must be installed in the building.
A selection of diagrams of the most common systems
is shown below. The arrangements shown are only
examples, and are no substitute for careful system
planning. Please visit the ROTEX website for more dia-
grams.
Short name
Meaning
1
Cold water distribution network
2
Hot water distribution network
3
Heating flow
4
Heating return flow
5
Mixing circuit
6
Circulation
7
Check valve, return valve
7a
Non-return valves
8
Solar circuit
3UV DHW
3-way distribution valve (hot water/heater)
3UVB1
3-way mixer valve (heater/internal boiler circuit)
CW
Cold water
DHW
Domestic hot water
DSR1
Pressurised solar system
FLS
FlowSensor - solar throughput and inflow tem-
perature measurement
H
1
, H
2
… H
m
Heating circuits
MAG
Diaphragm expansion vessel
MIX
3-way-mixer with drive motor
MK1
Mixer group with high-efficiency pump
MK2
Mixer group with high-efficiency pump (PWM-
regulated)
P
K
Boiler circuit pump
P
Mi
Mixing circuit pump
P
S
Solar operating pump
P
S1
Solar operating pump
P
Z
Circulation pump
RDS2
Pressure station
RoCon BF
Control GCU compact
RoCon M1
Mixer circuit control
RPS4
Solar control and pump unit
SK
Solar panel field
SV
Safety overpressure valve
t
AU
External temperature sensor
t
DHW
Storage tank temperature sensor
t
Mi
Inflow temperature sensor, mixer circuit
t
K
Solaris solar panel temperature sensor
t
R
Solaris return flow temperature sensor
T
S
Solaris storage tank temperature sensor
T
V
Solaris flow temperature sensor
VS
Scalding protection VTA32
Tab. 8-1 Abbreviations on hydraulics plans