d
068
92.
fm
SI-916 i-003R1 / SI-915 i-003R2
SI-912 i-004R3 / SI-912-018R4 /
SI-914-020R4
SERVICE INSTRUCTION
02 July 2021
79-00-00
Revision
Page 11 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
4) Appendix
The following drawings should convey additional information:
Fig. 1
Purging of oil system (916 i and 915 i Series)
1 Suction oil line
2 Oil return line(s)
3 Free end
4 Suitable container
5 Oil return line
6 Vent nipple
7 Cap or plug
8 Pressurized air connection