76-00-00
page 14
May 01/2007
Effectivity 914 Series
Edition 1 / Rev. 0
d02626
BRP-Rotax
Maintenance Manual
- Communication program:
Software between TCU and computer
tlr V4.3a for TCU part no. 966470 and 966471
tlr V4.5a for TCU part no. 966472 and 966473
tlr V4.6a for TCU part no. 966741
- Decoding unit (Dongle) with data cable to connect with
computer
◆
NOTE:
The Dongle is only required for the TCU part
no.
966470 to 966473. On the TCU part no.
966741, the computer must be connected
directly to the RS 232 plug connection, the 9-
pin port of the wiring harness.
◆
NOTE:
All the required components, except the computer, are
available in the form of a monitoring set (1) or as a
floppy disk (2).
Communication-
program
tlr V4.6a
00210
Communication-
program
tlr V4.3a
00210
00427
1
2
Fig. 76-9