![Rosslare MD-D04 Installation Manual Download Page 1](http://html.mh-extra.com/html/rosslare/md-d04/md-d04_installation-manual_1489222001.webp)
MD-D04
4-Reader Expansion Board
Installation Manual
1
1.
Introduction
The MD-D04 is an optional expansion board for use with Rosslare
Security's family of state-of-the-art AC-425 networked access
controllers.
The expansion board adds an additional four reader or keypad inputs;
four relay outputs and four supervised inputs to the access control
panel.
As a result, an access control panel with an MD-D04 expansion can
support a total of eight readers and eight door panels. In addition, it is
possible to add any keypad or biometric reader that supports the
Wiegand or Clock & Data transmission formats.
The host access controller has complete control over the additional
readers, inputs and outputs of the MD-D04 expansion board. The
inputs and outputs can be configured using an access control software
system such as Rosslare Security's AxTraxNG™. The software system
also configures the MD-D04's reader card transmission format and
input connection topology.
This guide explains how to install and begin working with your new
MD-D04 access control panel expansion board.
Figure 1: MD-D04 Access Controller Expansion Board
2.
Technical Specifications
2.1
Electrical Characteristics
MD-D04 Input Voltage
12 VDC
MD-D04 Input Current
(not including attached
devices))
Standby: 30 mA
Maximum: 190 mA
Number of Reader Ports
4
Number of Inputs
4
Number of Outputs
4
Output Relays
5
A with N.O., N.C., and COM contacts
Form-C Relays
Inputs Voltage
5 VDC maximum voltage
2.2
6B
Input Characteristics
Input Type:
Selectable as:
•
Normally Open
•
Normally Closed
•
Supervised with one resistor (three
states, normally open or normally
closed)
•
Supervised with two resistors (four
states, Normally Open or Normally
Closed))
2.3
7B
Physical Characteristics
Dimensions (L x W x D)
116 x 76 x 22 mm (4.57 x 2.99 x 0.87 in.)
Weight:
75 g (2.65 oz)
2.4
8B
Reader Characteristics
Reader Output Voltage:
12 VDC
Max. Reader Current:
245 mA
LED Control Output:
Open collector, Active low
Tamper Input:
5 VDC maximum voltage, optical anti-tamper
sensor
Supported Formats:
Various (refer to the AxTraxNG™ software manual)
2.5
9B
LED Indicators
Power LED:
Active when connected to a power source
Output LEDs:
Four LEDs
Each output LED is active when an output relay is
energized and N.O. to COM contacts are shorted.
3.
2B
Installation
Figure 2 shows how host access control panel looks before the MD-
D04 is attached.
3.1
10B
Attaching the MD-D04
1.
Disconnect power to the access control panel before attaching the
MD-D04.
2.
Remove the MD-D04 cover by lightly pulling one of the cover
knobs away from the circuit board. The entire cover comes away
from the board.
3.
Peel off the label on the cover of the panel marked "Remove to
install I/O board". The label is located on the same side of the
panel as the DIP switch.
4.
Insert the 10-pin male connector of the MD-D04 into the gap in
the panel cover labeled "IO EXPANSION SLOT" (Figure 2). The text
on the MD-D04 must face the same way as the text on the panel
cover.
5.
Tighten the screws securing the cover to the access control panel,
and the four Philips screws on the MD-D04 circuit board.
6.
Replace the cover on the expansion board, using it as a guide to
ease the MD-D04 into the panel's 10-pin female connector.
Figure 2: Host Access Control Panel without MD-D04 Expansion