Rosslare MD-D02B Installation Manual Download Page 1

MD-D02B 

 

2-Reader Expansion Module for AX-225x-B Control Panel 

Installation Manual 

1.

 

Introduction 

The MD-D02B is an optional expansion board for use with Rosslare’s  
AC-225x-B Networked Access Control panels. 
The expansion board adds an additional 2 Wiegand reader ports (supports 

keypads & RFID and Biometric) , 4 relay outputs (5 Amp 30V NO/NC Form-
C) and  4 supervised inputs with EOL to the access control panel. 
As a result, an access control panel with an MD-D02B expansion can 
support a total of four readers and four door panels. In addition, it is 
possible to add any keypad or biometric reader that supports the Wiegand 
or Clock & Data transmission formats. 
The host access controller has complete control over the additional 
readers, inputs and outputs of the MD-D02B expansion board. The inputs 
and outputs can be configured using an access control software system 

such as Rosslare AxTraxNG™. The software system also configures the MD-
D02B's reader card transmission format and input connection topology. 
This guide explains how to install and begin working with your new MD-
D02B access control panel expansion board.  

Figure 1: MD-D02B Access Controller Expansion Board 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Input Voltage 

12 VDC 

Input Current 

(not including attached devices) 

Standby: 30 mA 
Maximum: 190 mA 

Number of Reader Ports 

Number of Inputs 

Number of Outputs 

Output Relays 

5

 

A with N.O., N.C., and COM contacts Form-

C relays 

Inputs Voltage 

5 VDC maximum voltage 

2.2

 

Input Characteristics 

Input Type 

Selectable as: 

 

Normally Open 

 

Normally Closed 

 

Supervised with one resistor (three 
states, normally open or normally 
closed) 

 

Supervised with two resistors (four 
states, Normally Open or Normally 

Closed)) 

2.3

 

Physical Characteristics 

Dimensions (L x W x D) 

100 x 75.9 x 32.5 mm (3.9 x 3.0 x 1.3 in.) 

Weight 

98.2 g (3.46 oz) 

2.4

 

Reader Characteristics 

Reader Output Voltage 

12 VDC 

Max. Reader Current: 

245 mA 

LED Control Output 

Open collector, Active low 

Tamper Input 

5 VDC maximum voltage, optical anti-tamper sensor 

Supported Formats 

Various (refer to the AxTraxNG software manual) 

2.5

 

LED Indicators 

Power LED 

Active when connected to a power source 

Output LEDs 

Four LEDs 
Each output LED is active when an output relay is 
energized and N.O. to COM contacts are shorted. 

3.

 

Installation 

To install the MD-D02B expansion board: 

1.

 

Disconnect power to the access control panel before attaching the 
MD-D02B. 

2.

 

Remove the MD-D02B cover by lightly pulling one of the cover knobs 
away from the circuit board. The entire cover comes away from the 
board. 

3.

 

Peel off the label on the cover of the panel marked "Remove to install 
I/O board".  

 

The label is located on the same side of the panel as the DIP switch. 

4.

 

Insert the 10-pin male connector of the MD-D02B into the gap in the 
panel cover labeled "IO EXPANSION SLOT". 

 

The text on the MD-D02B must face the same way as the text on the 
panel cover. 

5.

 

Tighten the screws securing the cover to the access control panel, and 
the four Philips screws on the MD-D02B circuit board. 

6.

 

Replace the cover on the expansion board, using it as a guide to ease 
the MD-D02B into the panel's 10-pin female connector. 

 

Reviews: