Controller Operation
AYC-F/G/M60 Series Installation and Programming Manual
51
5.9.10
Setting the Lockout Feature
Using the lockout feature is highly recommended, especially
when using a short PIN code length (4 or 5 digits).
If the controller is presented with wrong codes (PIN or card)
consecutively several times, the unit goes into Lockout mode.
When a lockout occurs, the controller keypad and reader are locked
so no codes can be entered until the set lockout period expires.
During Lockout, the left LED is Off, the right LED flashes red, and the
controller beeps every two seconds. The default setting for the
Lockout Feature is 4000 (Lockout Disabled).
To set the lockout feature:
1.
Enter Programming mode.
2.
Press
6
to enter Menu 6.
The left LED flashes green.
3.
Construct a code using the following
instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, between 00 and 99; the
value is multiplied by ten, resulting in 0 to 990 seconds.
Green Green
Green