Controller Operation
42
AYC-F/Gx4 Series Installation and Programming Manual
3.
Construct a code using the following
instructions:
First digit
For Fail Secure Operation, the first digit should be
0
.
For Fail Safe Operation the first digit should be
1
.
Second digit
Siren Time in minutes (1–9, 0 – disabled)
Third and fourth digits
Enter the number of seconds (from 1 to 99) that you want
the Lock Strike to be released.
For example, 0312 means a Fail Secure Operation consisting of a
3-minute siren and a 12-second Lock Strike release time.
You hear three beeps.
The system returns to Normal mode.
The default value is 0004, which corresponds to Fail Secure
operation, no siren, and 4-seconds Lock Strike release time.
5.9.9
Defining the Auxiliary Input and Output
The default auxiliary setting is 2004.
To define the auxiliary input and output:
1.
Enter Programming mode.
2.
Press
6
to enter Menu 6.
The left LED flashes green.