background image

AY-B9250BT User Guide 

 

 

1.2.2.

 

REAR   

 

 

 

Fixed bracket 

Cable harness

 

Summary of Contents for AY-B9250BT

Page 1: ...AY B9250BT Professional Fingerprint Reader User Manual...

Page 2: ...l property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL...

Page 3: ...Door Lock 16 2 2 5 Network Type Lock Controller 16 2 3 Product Specification 17 3 Environment Setting 18 3 1 Checkpoints before Environment Setting 18 3 1 1 Menu 18 3 1 2 Administration authenticatio...

Page 4: ...3 8 1 DOORLOCK 49 3 8 2 RS485 52 3 8 3 WIEGAND 52 3 9 STATUS Menu 54 3 9 1 DB INFO 55 3 9 2 NETWORK 55 3 9 3 OPTION 55 3 9 4 INT DEVICE 55 3 9 5 EXT DEVICE 56 3 9 6 I O PORT 56 3 9 7 VERSION 56 3 10 R...

Page 5: ...on Do not install the terminal in humid or dusty places Otherwise it may cause malfunction Do not clean this terminal by sprinkling water nor wipe it with benzene thinner and alcohol Otherwise it may...

Page 6: ...AY B9250BT User Guide 6 1 2 1 FRONT Camera LCD Function KEY F1 F4 Speaker Card Sensor EM SC HID Fingerprint Sensor State LED BLE embedded USB assist device UDL10 connection...

Page 7: ...AY B9250BT User Guide 7 1 2 2 REAR Fixed bracket Cable harness...

Page 8: ...GND Power GND Power supply ground connection 8 GREEN R4A RS485A BI RS 485 interface 9 BLUE R4B RS485B BI RS 485 interface 10 ORANGE WO0 WIE_OUT0 OUT Output WIGAND WO0 11 YELLOW WO1 WIE_OUT1 OUT Output...

Page 9: ...name LC015B RS485A R4A green 485A RS485B R4B blue 485B ground connection GND black GND DOOR MONITOR IN1 If this pin is not used connect to GND pin INSIDE OPEN IN0 DC12V LC015B separate power supply DC...

Page 10: ...ction State NONE Normal Sensed by fire detector valid on DM2 fire set BLE connection State NONE Disconnected with Admin App Connected with Admin App MCP040 connection State NONE MCP040 is not used Nor...

Page 11: ...DISABLE 1 3 4 Main Screen Operating in Exclusive mode Initial Screen Operating in Network mode Initial Screen Operating in Dummy mode Initial Screen Operating in lock mode Reject all users authenticat...

Page 12: ...g authentication time OFF GREEN Normal OFF LOCK OPEN ON Authentication Success ON Maintain during authentication time OFF BLUE Terminal Normal alive Flash at intervals of 5 seconds Function Key LED En...

Page 13: ...by using your forefinger if possible The fingerprint cannot be correctly registered and entered only by your fingertips The center of the fingerprint should be touched with the fingerprint input sect...

Page 14: ...to verify your ID via fingerprint The use of the fingerprint recognition technology Biometrics can prevent forgetting your password losing your card or key or avoid the risk of their theft The use of...

Page 15: ...ock 2 2 2 Single Type Lock Controller 2 2 3 Dummy Type Door Lock Lock control BLE 2 4G Mobile App T2 Close Open Lock Controller Mobile App RS485 BLE 2 4G T2 Close Open RS485 Ethernet Server AY B9250BT...

Page 16: ...ork Type Door Lock 2 2 5 Network Type Lock Controller Lock Control BLE 2 4G Mobile App Close Ethernet Open T2 Door Lock Ethernet Internet Server Internet RS485 Lock Controller BLE 2 4G Mobile App Ethe...

Page 17: ...tication Speed 1 N within 1 sec based on 1 000 fingerprints Fingerprint capacity 20 000 Fingerprints 10 000 users Two identical fingerprints registration per user Note Similar fingerprint inspection i...

Page 18: ...dministrator is registered the admin authentication screen is displayed at first as follows Administrator authentication Administrator authentication is progressed with fingerprint and card You can ac...

Page 19: ...While case opens make DIP of rear side switch ON state as follows Power terminal ON After the terminal completely booted Press F1 longer to enter the menu with buzzer sound Ppiririk Caution You should...

Page 20: ...IME OUT PING 60sec MENU OPTION LOCKING NO USE MENU INT DEVICE FP SENSOR 1 1 LEVEL 5 MENU INT DEVICE FP SENSOR 1 N LEVEL 8 MENU INT DEVICE FP SENSOR LFD LEVEL NONE MENU INT DEVICE FP SENSOR AUTH TIME 5...

Page 21: ...r N C MENU EXT DEVICE DOORLOCK DM2 NONE MENU EXT DEVICE RS485 TYPE NONE Single Type Lock Controller LC010 3 1 6 3 Menu position Possible setting MENU NETWORK NO USE MENU EXT DEVICE DOORLOCK LOCK1 TYPE...

Page 22: ...C MENU EXT DEVICE DOORLOCK LOCK2 TYPE NONE MENU EXT DEVICE DOORLOCK DM1 NONE MENU EXT DEVICE DOORLOCK DM2 NONE MENU EXT DEVICE RS485 TYPE NONE Network Type Door Lock MOTOR 3 1 6 7 Menu Position Possi...

Page 23: ...8 0 3 SN 255 255 255 0 GW 192 168 0 1 MENU NETWORK USE SERVER IP 192 168 0 2 PORT 7332 MENU EXT DEVICE DOORLOCK LOCK1 TYPE NONE MENU EXT DEVICE DOORLOCK DM0 NONE MENU EXT DEVICE DOORLOCK LOCK2 TYPE NO...

Page 24: ...2 3 Set in terminal In order to connect the terminal to the server set to the network mode and set the information Move to MENU NETWORK USE TERMINAL and check whether lower information is correct or n...

Page 25: ...the server network information it is displayed as follows 3 2 4 LAN connection in terminal At first you can see the unregistered state because the terminal is not registered 3 2 5 Register the termin...

Page 26: ...AY B9250BT User Guide 26 If the registration is successful the screen is displayed as follow For more details about Rosslare Bio9000 operation please refer to the guide document...

Page 27: ...RD is not admitted to set up state check only Password AUTO ADD FP UID FP1 FP2 OK Card UID Card OK MODIFY INPUT ID Authentication Type Card FP MCARD Authentication Condition OR AND MCARD is OR conditi...

Page 28: ...ANGUAGE ENGLISH 0 KOREAN 1 INDONESIAN 2 MULTILINGUAL 3 ARABIC 4 SPANISH 5 PORTUGUESE 6 FRENCH 7 RUSSIAN 8 FARSI 9 JAPANESE 10 CHINESE 11 SHOW ID NO YES USER LOGO NO USE USE USER ID LEN 4 16 SAVE LOG S...

Page 29: ...or2 Schedule alarm OPEN TIME 3 1 20sec OPEN ALARM TIME 5 0 20sec 0 No Alarm 1 20 Alarm DM0 NONE Lock Normal Open Lock Normal Close DM1 NONE Lock Normal Open Lock Normal Close DM2 Not use Normal Open N...

Page 30: ...TID xxxx NET YES MODE TN NET TYPE STATIC ENCRYPT DES CIP SN GW xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx MAC xx xx xx xx xx xx SIP PORT xxx xxx xxx xxx xxxx OPTION ATTEND M2 F1 F4 AUTO TNA YES...

Page 31: ...RS485 LC010 RS485 ID xxx WIEGAND IN OUT 34B 34B SITECODE xxx SEND USERID I O PORT LOCK1 HIGH LOCK2 HIGH DM0 HIGH DM1 HIGH DM2 HIGH W0IN HIGH W1IN HIGH INSIDE HIGH TAMPER SW HIGH VERSION HW FW Card BL...

Page 32: ...Use to add certification conditions card or fingerprint of registered user DELETE Use to delete a registered particular user DELETE ALL Use to delete all registered users 3 4 1 ADD USER TYPE 3 4 1 1...

Page 33: ...conditions should be satisfactory and authentication succeeds FP 0 FP is abbreviation of Finger Print 0 means the registered FP number 1FP means 2 fingerprints CD 0 CD is abbreviation of CARD 0 means...

Page 34: ...No Display Method Standard 529D06E3 8digits Hex 3 4 2 AUTO ADD AUTO ADD is used when you want to register general users not admin user consecutively with card or fingerprint If you select FP it adds...

Page 35: ...modifying the authentication type of the registered user In authentication type authentication type fingerprint card and authentication condition AND OR can be changed If the modification type is modi...

Page 36: ...internally is sent to sever If you want to see the authentication log data in Standalone mode move RECOVERY BACKUP LOG EXPORT from main menu download it in USB through UDL module and check it by Ross...

Page 37: ...on is processed only in server Terminal Terminal only Authentication is processed only in terminal Even if it is Terminal Only authentication log is sent to server In Server Only mode if the network i...

Page 38: ...Category Default Setting Value Terminal IP 192 168 0 3 SUBNET MASK 255 255 255 0 GATEWAY 192 168 0 1 It can set the address value as follows Function Key Function Explanation F1 Increase the setting v...

Page 39: ...ATTEND TNA related menu is configured Category Explanation TYPE When Function Key is used in time and attendance option it is used AUTO TNA Use to determine whether to remain Function Key or not show...

Page 40: ...s if you don t use AUTO TNA AUTO TNA 3 6 1 2 AUTO TNA is the menu to determine whether to remain continually the setting TNA mode or not Category Explanation NO The TNA mode is automatically returned...

Page 41: ...d Chinese Language support for some text is in Farsi Arabic Thai and Russian SHOW ID 3 6 2 2 It is used to determine whether to show your ID at the time of authentication success window Category Expla...

Page 42: ...the customer s image it should be edited in the red box as the left picture The full image size is 128 W x160 H pixel and the red box image size is 102 W x74 H pixel USER ID LEN 3 6 2 4 It is used to...

Page 43: ...layed in the default screen YY Year MM Month DD Day Through SETTING you can set current Year Month Day and Time 3 6 3 SAVE It is the menu including the function related to SAVE LOG SAVE 3 6 3 1 It is...

Page 44: ...d to set the authentication result display how long it keeps for a seconds The setting range can be set from 0 to 5 seconds If it set to 0 then don t display the authentication result NET ERROR 3 6 4...

Page 45: ...ting range is available for 30 255 seconds 3 6 5 LOCKING Locking mode is the function that it rejects the authentication of all users until the administrator enters the menu and releases the locking m...

Page 46: ...TIME BEEP Set Beep Sound VOICE Set Voice Sound BLE BLE registration mode TAMPER Set the alarm when opening terminal case 3 7 1 FP SENSOR For the fingerprint recognition it sets for the user registrati...

Page 47: ...er and higher the ability to prevent the input of duress fingerprint produced by rubber paper film and silicon etc reinforces but too dry fingerprint cannot be input well Also the authentication speed...

Page 48: ...al in Administrator s App this menu is required By using this menu it can make the terminal BLE READY Only if the terminal is BLE READY it can perform the registration procedure of the terminal after...

Page 49: ...ollows Category Explanation DOORLOCK It sets the control device to lock through the internal relay RS485 It sets the devices using RS485 WIEGAND It sets the device using WIEGAND 3 8 1 DOORLOCK It is t...

Page 50: ...t to mark authentication failure in Lock 2 MOTOR2 When connecting motor lock LOCK2 OPEN TIME 3 8 1 4 If Lock 2 sets FAIL IND it sets the time to give the signal The default value is 3 seconds and the...

Page 51: ...s the input port and it is used to detect the signal state of lock DM2 3 8 1 8 DM2 Door Monitor 2 is the input port and it is used to detect a various of sensor and alarm For example if connecting wit...

Page 52: ...e SR100 FP Dummy Reader When it installs the other FP dummy reader device in external and then operates it is used MCP040 Terminal operates as the dummy reader If Terminal is connected with MCP040 dev...

Page 53: ...nation NONE WIEGAND input port is not used WIE26BIT EM HID26 Card Module WIE34BIT MIFARE Card Modules CUSTOM Use Access Manager program and set Wiegand format WIRE OUTPUT 3 8 3 2 Category Explanation...

Page 54: ...ty 1 Site Code 8bit ID 16bit O Parity 1 34 Bit E Parity 1 Site Code 8bit ID 24bit O Parity 1 If the length of the User ID greater than 8 and sent in the following format without site code E Parity 1 I...

Page 55: ...o the external device I O PORT Display the current signal of Input Output port that interfaces with outside VERSION Display the version of the equipped device in the terminal 3 9 1 DB INFO It displays...

Page 56: ...6 I O PORT It reflects the current I O Port state and displays it on the screen Output Port LOCK1 LOCK2 Input Port DM0 DM2 W0IN W1IN INSIDE Open Tamper When the input port shorts GND the signal modif...

Page 57: ...TE REBOOT REBOOT 3 10 1 INITIALIZE It is used to initialize CONFIG LOG DB and FACTORY in the terminal CONFIG 3 10 1 1 It is used to initialize the modified setting value in the menu as the default val...

Page 58: ...current data can be lost when you setting wrong 3 10 2 SELF TEST It is used when the terminal tests the operation state about internal external device by itself INT DEVICE 3 10 2 1 It could test VOIC...

Page 59: ...nsor Test FP Sensor Test is used to test the operation state of FP sensor from terminal Input your fingerprint twice if they are same it shows Success screen Otherwise if not it shows Failure screen C...

Page 60: ...Explanation DOORLOCK Lock1 Lock2 SENSOR IN DM0 DM1 DM2 INSIDE OPEN TAMPER DOORLOCK Test It is used to check the state of LOCK1 LOCK2 OPEN CLOSE from the terminal The procedure is as follows SENSOR IN...

Page 61: ...rted for all USB memory UDL module may not work depending on the USB memory size manufacturer and method If Terminal detect UDL Device and USB memory icon is displayed in the default screen If icon is...

Page 62: ...DB saved in the terminal back up first and try to input the user It opens USER NDB file in USB memory and brings into the terminal through UDL The user registration data that you brought is reflected...

Page 63: ...rprint The same fingerprint as the input fingerprint is identified among the registered fingerprints without User ID or Card entered This is called One to N Identification Authentication Level As a le...

Page 64: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee t...

Page 65: ...250BT User Guide 65 Appendix 3 Radio Equipment Directive RED Rosslare hereby declares that the AY H6355BT is in compliance with essential requirements and other relevant provisions of Directive 2014 5...

Page 66: ...6 Appendix 4 RoHS Directive Under our sole responsibility that the following labeled AY U9xxBT is tested to conform to the Restriction of Hazardous Substances RoHS directive 2011 65 EU in electrical a...

Page 67: ...rosslaresecurity com Europe Rosslare Israel Ltd 22 Ha Melacha St P O B 11407 Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin Ameri...