Rosslare AS-36 Installation Instructions Download Page 1

 

AS-36/SA-36G/H/W 

Installation Instructions 

Maximum Heat Detector 

 

0706-00    

  

1.

 

Introduction 

The AS-36 maximum heat detector sounds an alarm 

whenever the unit temperature reaches 55±2ºC. The 

unit is supplementary to smoke detectors and should be 

placed only in areas where smoke detectors cannot be 

used. AS-36 is operated by a single 9V battery, which 

can sustain the unit’s operation for up to 1 year.  
AS-36 has an 85-decibel horn, test button, and an alarm 

LED indicator. The AS-36 heat detector is ideal for 

kitchens, garages, cellars, boiler rooms, attics and other 

areas where there are normally high levels of fumes, 

smoke or dust which preclude the use of smoke 

detectors due to the risk of false alarms.  
The detector can connect to Rosslare's security system 

panel, or to any standard wireless security system. To 

connect the AS-36 Maximum heat detector to a wired 

or wireless system, mount it on Rosslare's SA-13G 

(wireless; 433.92MHz), SA-13H (wireless, 868.35MHz), or 

SA-13W (wired) base.  

NOTE: A fully mounted unit (AS-36 + SA-13G/H/W) 

is referred to as SA-36G/H (wireless) or SA-36W 

(wired). 

NOTE: The AS-36 maximum heat detector is not 

designed to serve as a substitute for a primary fire 

detection system.  

 

Figure 1: AS-36 Unit 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

AS-36 Detector Current:   

 

Maximum alarm: 150 mA 

Standby: 10 µA 

SA13G/H Base Current:   

 

Transmitting: 16 mA 

Standby: 16 µA 

 

Transmitting distance: up to 200m in open 

space 

SA13W Base Current: 

 

 

  Operating: 7 mA 

NO output: 

  Standby: 10 mA 

NC output: 

  Standby: 21 mA 

 

  Operating: 23 mA 

Battery:  

1604A (9V Alkaline) 

Battery Life: 1 year 
Low Battery Detection: 

 

Last 7 days of battery life 

2.2

 

Environmental Characteristics 

Use Environment: Indoor  
Operating Temperature:  0º–60ºC (32º–140º F) 
Operating Humidity: 

2.3

 

Physical Characteristics 

10% to 90% non-condensing

 

Sensitivity:     Alarm temperature 55±2ºC 
Alarm Indication: LED and siren 
Indicators Siren Volume:  85dB at 3m (10ft)   
Dimensions:
  AS-36:  

118.4 x 107 x 40 mm  

   

4.66 x 4.21 x 1.57 inch 

  SA-36G/H  126.5 x 124 x 63.7 mm 

   

4.98 x 4.88 x 2.5 inch 

  SA-36W: 

121 x 112.6 x 58.5 mm 

   

4.76 x 4.43 x 2.3 inch 

Weight:

 

  SA-36W: 

176g (6.2 oz)

  

 

  AS-36: 

130g (4.59oz) 

  SA-36G/H:  291.3g (10.27 oz) 

3.

 

Installation 

The SA-36 is a heat detector; it can be operated as a 

standalone unit or as an alarm system together with the 

SA-13 wireless or wired base. 

3.1

 

Wiring the SA-36W  

For wiring instillations follow the instructions below. 

To set and wire the SA-36W: 

1.  set the alarm output setting to either Normally 

Open or Normally Closed using the select switch on 

the SA-13W. 

2.  Connect the power between the Security Alarm 

system and the SA-13W’s Vin and ground terminal 

blocks. 

3.  Connect the Tamper outputs to the Security Alarm 

system’s inputs 

4.  Connect the Alarm terminal blocks to the Security 

Alarm system, refer to the installation manual of the 

alarm system you are connecting the detector to.  

Reviews: