5.1
DIP Switch Configuration
The AC-425 panel DIP switch controls a number of operating parameters, including the
device address and baud rates for serial communication.
Figure 15: DIP Switch
The following is a list of DIP switch numbers and their functions:
DIP
Switch
Function
1
Panel's communication baud rate.
2
3
Panel type
Defines the number of readers for each door – one or two readers per door. This will
also affect the number of doors controlled by the panel.
4
AC-425 panel's RS-485 network address.
5
6
7
8
Power off the access control panel before changing the DIP switch settings.
After changes have been made, reboot the panel. The new settings are automatically
defined after power up.
5.2
AC-425 Panel Baud Rate
The AC-425 panel serial port baud rate, set in DIP switches 1 and 2, defines the
communication speed for connecting with a PC in a network connection.
The default baud rate is set to 9600 bits per second.