background image

Phone: +1 613-652-4886 • Technical Support: +1 613-652-4886 • www.rossvideo.com • 4910DR-220-01 • March 22, 2018

Wheatstone®

The information in this document applies to the Wheatstone® 
D-Series, E-Series, G-Series, SR9, and Glass-E audio 
mixers.

Requirements

• Large Audio Mixer Interface Software Option
• Ethernet Cable

Port Connections

Remote Device Port Configuration Settings

Use the following procedure to configure a remote device for 
your Wheatstone® on the Caprica Server:

1.

Use the current version of 

DashBoard

 software to 

connect to your 

Caprica Server

.

2.

In the 

DashBoard Tree View

, double-click the 

Port 

Configuration

 node of your Caprica Server.

3.

In the 

Port Configuration Summary

 table, double-click 

REMOTE#

 port in the 

Port

 column.

4.

In the 

Configure REMOTE#

 panel, click 

Audio Mixer

.

5.

Click 

Wheatston

.

6.

Click 

Network Settings

.

7.

Use the following settings to configure the 

Network 

Settings

 for your Wheatstone®:

Ethernet Role

 — Client

Remote IP Address

 — IP address of the 

Wheatstone® audio mixer

Remote Port

 — 55777

Local IP Address

 — 0.0.0.0

Local Port

 — 0

Protocol

 — TCP

8.

Click 

Device Settings

.

9.

In the 

Freq

 box select or enter a frequency for the 

Wheatstone®. The default frequency is 5.

10.

Click 

Apply Changes

 to save the device settings.

11.

Click 

Done

 to close the Configure REMOTE# panel.

For More Information on...

• configuring remote devices for OverDrive systems that 

contain a Caprica Server, refer to the 

Caprica User Guide

.

Device Setup

The Wheatstone® must be set up for TCP communications 
on port 55777.

Compatibility

Contacting Technical Support

Technical Support is staffed by a team of experienced 
specialists ready to assist you with any question or technical 
issue.

Ross Video has technical support specialists strategically 
located around the globe to ensure a prompt response to 
technical inquiries. Our primary technical support center is 
located in Ottawa, Ontario, Canada. In addition, we have 
offices in The United Kingdom (London), Australia (Sydney), 
and Singapore with satellite locations in New York City, The 
Netherlands, and China. As we expand our presence 
globally, we are constantly evaluating other key locations to 
have a local technical support specialist in order to better 
service our customers.

North America

Our North America center located in Ottawa, Ontario, 
Canada and is open Monday to Friday 8:30 a.m. to 6:00 p.m. 
EST, with 24/7/365 on-call service after hours.

Our telephone number is: +1-613-652-4886

Toll free within North America: +1 844-652-0645

EMEA

Our EMEA center is located in Buckinghamshire, England, 
United Kingdom and is open Monday to Friday 8:30 a.m. to 
5:00 p.m. GMT. After hours support is provided by our North 
America location.

Our telephone number is: +44 (0)1189502446

International toll free: +800 1005 0100

Communications

Audio Mixer

 

Ethernet

>

Local Area Network

 

Ethernet

Audio Mixer

Version

Wheatstone®

-

Automation

OverDrive

15.0 or higher

Caprica Server

2.2c or higher