TRA-8206 User Manual (Iss. 05)
User Controls • 3–7
Factory Default Values
Any channel can be set back to factory settings, where the data rate is set to
AUTO
and the alarm
is enabled on loss of input.
Use the following procedure to reset a channel to factory default values:
1.
Press and hold the
Bootload
button on the card.
2.
Press the rate selection button for the selected channel. The
Signal Status LED
flashes
green and red for approximately 2 seconds to confirm the reset values.
Channel #
OK/ERROR
Green
When lit, this LED indicates that the specified channel is
reclocking a valid signal.
Red
When red, this LED indicates that the channel cannot reclock due
to an invalid signal or rate setting.
Table 3.2 LEDs on the TRA-8206
LED
Color
Display and Description