Synergy Series Operation Guide (v18)
Keying • 7–13
With the feature enabled, the clean feed alpha signal is routed to the DVE, thus
removing the DVE Send limitations with Squeeze & Tease, Chroma and Auto Select
keys as described above.
•
If the
AlphaNomadCK
mode is assigned on the
Clean Feed Menu
, the clean feed
output will follow the last selected Chroma key. In the Clean Feed From Menu, the MLE
will be locked to the bottom MLE. When a Chroma Key is selected on any Keyer in any
of the MLEs, the clean feed signal will change to the alpha signal for the selected Keyer.
•
If the
Alpha Key 1
mode is assigned on the
Clean Feed Menu
, the clean feed output
will be the alpha for Key 1 of the selected MLE.
•
If the
Alpha Key 2
mode is assigned on the
Clean Feed Menu
, the clean feed output
will be the alpha signal for Key 2 of the selected MLE.
Please consult with your facility engineer to determine how your Synergy switcher is configured.
Refer to the section, “
Clean Feed Setup
” of the
Synergy Series Installation Guide
, for full details.
Important
With
DVE Alpha
selected and the clean feed alpha signal routed to
the external DVE, the switcher’s
Clean Feed
output signal (on the
CLEAN
output connector) is lost.
Summary of Contents for SYNERGY 4000DR-003
Page 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Page 10: ......
Page 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Page 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Page 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Page 242: ...7 68 Keying Synergy Series Operation Guide v18...
Page 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Page 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Page 332: ...IX 22 Index Synergy Series Operation Guide v18...