![Ross Synergy 2 SD Installation Manual Download Page 270](http://html1.mh-extra.com/html/ross/synergy-2-sd/synergy-2-sd_installation-manual_1489028270.webp)
9–40 • Additional Installation Setups
Synergy Series Installation Guide (v18)
4. Press
Remote GPI Type
to display the
Remote GPI Type Menu
.
Remote GPI Type Menu
5. Set up the desired remote GPI trigger type as follows:
•
Use the
Remote
knob to select the remote GPI that you want to set the GPI type
for.
•
Use the
Type
knob to select the type of control that you want to assign. You can
select between the following:
~
Low-Override
— Select this option for an input trigger to cause a temporary
override on contact closure (high to low signal). When the contact opens again
(low to high signal), any override on this Aux Bus is ended, and the Aux Bus
output returns to its selected crosspoint. A
Low-Override
trigger acts as an
override of the actual crosspoint selected, but can also be cancelled
(overridden) simply by pressing another crosspoint. This is the default setting.
~
Low-Toggle
— Select this option for an input trigger to cause an override on
initial contact closure (high to low signal) if no override exists currently on this
Aux Bus. The override remains in effect until the contact is closed a second
time (assuming no other action has ended the override). A
Low-Toggle
trigger
acts as an override of the actual crosspoint selected, but can also be cancelled
(overridden) simply by pressing another crosspoint.
~
High-Toggle
— Select this option for an input trigger similar to the
Low-Toggle
, except that an override is triggered when a contact is opened (low
to high signals).
~
Latch
— Select this option for an input trigger that will override the Aux Bus
output with the selected crosspoint until overriden by another CCU joystick, a
remote aux panel crosspoint button selection, or a switcher Aux Bus crosspoint
button selection.
~
Off
— Select this option to disable the highlighted remote GPI.
This concludes the procedure to configure your CCU Joystick Aux control.
Note
The text above the
Remote GPI Type
label indicates the type of
trigger selected for the highlighted remote GPI. This information
tracks each GPI as you rotate the top
Remote
knob.
Note
The text above the
Remote GPI Assignment
label indicates the
Aux Bus and BNC assigned to the highlighted remote GPI. This
information tracks each GPI as you rotate the top
Remote
knob.
Summary of Contents for Synergy 2 SD
Page 1: ...Ross Video Limited Installation Guide Volume I Software Issue 18...
Page 10: ......
Page 18: ...viii Contents Synergy Series Installation Guide v18...
Page 88: ...2 44 Installation Synergy Series Installation Guide v18...
Page 122: ...4 18 Preliminary Video Installation Synergy Series Installation Guide v18...
Page 132: ...5 10 Using the Menu System Synergy Series Installation Guide v18...
Page 156: ...6 24 BNC Configuration and Check Synergy Series Installation Guide v18...
Page 292: ...9 62 Additional Installation Setups Synergy Series Installation Guide v18...
Page 326: ...11 10 Still Stores Synergy Series Installation Guide v18...
Page 346: ...12 20 Editors OverDrive Synergy Series Installation Guide v18...
Page 394: ...GL 4 Glossary of Terms Synergy Series Installation Guide v18...