Synergy 100 MD Operator’s Manual (v7.2 MD-S100)
Position/Crop Functions • 13–3
Channel Position
The
Position Menu
allows you to adjust the position of the channel in the 3D space. You can use the
Positioner or the
HUE
,
SAT
and
LUM
knob to adjust the position of the channel.
Use the following procedure to adjust the position of a channel:
1. Navigate to the
Position/Crop Menu
as follows:
•
Press
FLY KEY
in the
Effects Keyers Group
.
•
Press
MENU
to display the
Main Menu
.
•
Press
8. S&T MD
to display the
S&T MD Menu
.
•
Press
0. Position/Crop
to display the
Position/Crop Menu
.
2. Press
0. Position
to display the
Position Menu
.
Position/Crop — Position Menu
Use the
knobs
in the
Mattes Group
as follows to adjust the position of the channel:
•
X-Axis
— Use the
HUE
knob to adjust the horizontal position. (Positive values move
the channel to the right.)
•
Y-Axis
— Use the
SAT
knob to adjust the vertical position. (Positive values move the
channel up.)
•
Z-Axis
— Use the
LUM
knob to adjust the distance the channel is from the center point.
(Positive values move the channel away from you.)
Use the
Positioner
as follows to adjust the position of the channel:
•
X-Axis
— Move the
Positioner
left
or
right
to control the horizontal position of the
channel on screen.
•
Y-Axis
— Move the
Positioner
up
or
down
to control the vertical position of the
channel on screen.
Operating
Tip
You can select both
Key 1
and
Key 2
at the same time by
double-pressing the
KEY2
button in the
Effects Keyers Group
. Both
Keys must be Flying.
Operating
Tip
You can use the
POSN
hotkey to display the
Position/Crop Menu
directly.
Operating
Tip
Using the positioner allows you to move the channel into position
more quickly than using the knobs.
Use positioner or Hue, Sat, Lum to modify
Position/Crop
1 2 U O1 O2 Key 1
0. Position
1. Rotation
2. Pivot Preset
3. Pivot Position
4. Aspect
Off
5. Crop Horizontal
6. Crop Vertical
7. Transp.
8. Freeze
9. Adv. Positioning
Position X: 0.0
Y:
0.0
Z:
0.0
Off
Off
Summary of Contents for Synergy 100 MD
Page 1: ...Ross Video Limited Operator s Manual Software Issue 7 2 MD S100...
Page 10: ......
Page 50: ...2 10 Control Panel Introduction Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 62: ...3 12 Using the Menu System Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 80: ...4 18 Switcher Basics Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 148: ...7 42 Keying Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 182: ...10 12 Peripheral Control and More Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 210: ...11 28 Global Store Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 238: ...12 28 Squeeze Tease MD Basic Operation Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 256: ...14 6 Advanced Positioning Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 276: ...16 8 Preprocessor Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 316: ...17 40 Squeeze Tease MD Sequences and Wipes Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 376: ...21 4 Appendix B Synergy Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 382: ...22 6 Appendix C Hotkeys Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 386: ...GL 4 Glossary of Terms Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 402: ...IX 16 Index Synergy 100 MD Operator s Manual v7 2 MD S100...