9–2 • Calibration and Diagnostics
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
Switcher Calibration – Synergy 1
The
Calibration Menu
allows you calibrate all analog controls on the switcher panel, including the
faders, the XYZ positioner, and all knobs (excluding those to the right of the display).
Calibrating the Synergy 1 Switcher
The
Calibration Menu
provides a visual display of all analog controls, including the fader,
positioner, and all knobs.
Use the following procedure to calibrate the analog controls of the Synergy 1 switcher:
1. Navigate to the
Calibration Menu
as follows:
•
Press
HOME
(to display
Main Menu 1-2
)
•
MORE
(to display
Main Menu 2-2
)
•
Setup
(to display the
Setup Menu
)
•
Installation
(to display
Installation Menu 1-2
)
•
MORE
(to display
Installation Menu 2-2
)
•
Calibration
(to display the
Calibration Menu
)
2. To calibrate the fader:
•
Move the fader gently to its upper and lower limits.
•
Repeat this procedure two or three times.
•
As you move the fader, values appear in the
Main Area
, under the
FADER
heading.
3. To calibrate the positioner, move
each axis
as follows:
•
Calibrate the
X-Axis
by moving the joystick all the way to the left then all the way
to the right. Repeat this procedure two or three times.
•
Calibrate the
Y-Axis
by moving the joystick all the way up then all the way down.
Repeat this procedure two or three times.
•
Calibrate the
Z-Axis
by twisting the joystick knob fully clockwise and
counterclockwise. Repeat this procedure two or three times.
As you move the joystick, you will see a series of values appear in the
Main Area
,
under the
POSITIONER
heading. The numbers for each axis
may not match
— this is
normal.
Important
It is strongly recommended that you calibrate
all analog controls
on
your switcher. Failure to do so may store false limit information into
any controls that may have been “bumped” during the calibration
process — which in turn will prevent proper switcher operation.
Caution
Use the Calibration Mode with caution.
Perform the calibration only when you suspect that there has been
“drift” in the knobs or the joystick, or that there is a “limit” problem
with a fader.
Note
Do not use force as false upper and lower fader limits may be
programmed in beyond the rubber stops.
Summary of Contents for Synergy 1
Page 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Page 10: ......
Page 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Page 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...