![Ross RCS-8120 User Manual Download Page 14](http://html1.mh-extra.com/html/ross/rcs-8120/rcs-8120_user-manual_1488966014.webp)
Cabling
This section provides instructions for connecting cables to the RCS-8120 before mounting the chassis
into the rack bay near the frame holding the switcher cards.
Connect switch A of the RCS-8120 to the utility switch via J2 (for AVS-7864) or V1 (for DSS-8024
and AVS-8064). If using the 3 pin audio connector, use a good quality audio/control cable (i.e. Belden
1503A 22AWG shielded pair). Connect switch B of the RCS-8120 to the utility switch via J4 (for
AVS-7864) or V2 (for DSS-8024 and AVS-8064). See the following Figure.
Figure 4. RCS-8120 Cable Connector Locations
Rear Plug-on Connector Wiring
Wire the external cables to the plug-able terminal block connectors as outlined in the diagram and
procedure below.
Figure 5. Connector Wiring for Remote Control Selectors
1. Insert the designated wire to the appropriate slot on the connector. See the figure
above for details.
2. Use a tweaker screwdriver to tighten the corresponding screw on the underside of
the connector.
3. Repeat steps 1 and 2 for each wire on each connector.
Once the cables have been wired to the connectors, install the connectors to the sockets on the
RCS-8120 module so that the slotted tongue fits in the grooves on the module socket.
2-4
•
Installation and Setup
RCS-8120 User Manual (Iss. 01A)