Value
Option
Select whether the tally light on the camera is
controlled by the switcher (
Yes
) or not (
No
).
Tally
Select whether the switcher selects another
camera before selected the desired camera
(
ON
), or selects the desired camera
immediately (
OFF
).
Toggle Cam
Select the maximum tilt speed for the camera
head.
Tilt Speed
Select the maximum zoom speed.
Zoom Speed
Select the speed that height or elevation
changes are performed.
Z Speed
RossTalk Extra Options
Value
Option
Select whether the switcher sends an
acknowledgement after receiving a RossTalk
command (
ON
) or not (
OFF
).
Cmd
Response
Router Extra Options
Value
Option
Select whether the router starts counting
switcher sources at 0 or 1.
Base
Select the number of destination crosspoints
that are available on the router.
Dest Xpts
Select whether the router starts counting levels
at 0 or 1.
Level Base
Select the number of levels that the router is
using. This sets the number of levels that the
router switches when the input BNC from the
router is set to All levels.
Num Levels
Select whether the router starts counting source
and destinations at 0 or 1.
Src & Dest
Base
Select the number of source crosspoints that
are available on the router.
Src Xpts
Serial Tally Extra Options
Value
Option
Select whether the switcher reports that nothing
is on-air when the switcher is at black (
All Off
),
or have the switcher not report anything
different when it goes to black (
Active On
).
At Black
Select the message size protocol for the tally
device. You can select
Minimal
,
Normal
, or
Complete
.
Data Txfr
Select the rate, in fields, between update
messages sent by the switcher to the tally
device.
Rate
Value
Option
Select theME that you want to assign to ME
slot
X
on the tally device.
Slot X
Select whether the switcher used the source
names from the router (
Router Src
), or from
the input BNC (
BNC Name
).
Source Name
Select whether the switcher sends
None
or
Init
as the start message for the tally device.
Start
Switcher Extra Options
Value
Option
Select whether the switcher sends a ping after
10 minutes of inactivity (
On
) or not (
Off
). This
is designed to keep the connection active
between the two devices so that network
monitoring equipment don't close the
connection. The ping message sent is
NOOP<CR><LF>
.
Ping
UMD Extra Options
Value
Option
Select whether to include header data when
communicating to a TCP device (
Header
) or
not include the data for a serial device (
No
Header
). If you are using a DeviceMaster
®
to
communicate with a serial device
Add Header
Select the brightness value (
0
to
3
) that is sent
to the UMD device.
Brightness
Selects how tallies are displays and shows the
active state of the keyer.
•
Standard
— tallies are displays with
preview on the left and program on the
right.
•
Inverted
— tallies are displays with preview
on the right and program on the left.
•
Bus Messages
— tallies are displayed on
the right only and the left tally bits are used
to show the active state of the keyer.
•
Bus Messages Inv
— tallies are displayed
on the left only and the right tally bits are
used to show the active state of the keyer.
Invert
Select how the mnemonic names are justified
on the output (
Left
,
Right
, or
Center
).
Justify
Select whether the switcher shows the
mnemonic names from the UMD device on the
MultiViewer (
ON
) or the internal source names
(
OFF
). The labels for the MultiViewer boxes
must be turned on to see the names.
MV Names
Select whether the switcher sends 1 (
Slow
) or
70 (
Fast
) messages per field to the UMD
device.
Rate
Select the address of the screen that you want
to send the information to (
0
to
65535
).
Screen
66
• Device Control — Acuity Setup Manual (v9.2)
Summary of Contents for Acuity 4410AR-020