7–8 • Specifications
ACO-4400A User Manual (Iss. 03)
Physical Specifications
Clearance
Mechanical Characteristics
Environment Characteristics
Table 7.6 Clearance
Category
Performance Requirement
Reference Information
Clearance
Side
50mm (2.00in)
Rear
75mm (3.00in)
Table 7.7 1Hz Frequency Reference Output
Category
Performance Requirement
Reference Information
Height
43.5 mm (1.71”)
Width
482.5 mm (19.00”)
Depth
405 mm (15.95”)
Net Weight
5.85 kg (12.9lbs)
Table 7.8 Environment Characteristics
Category
Performance Requirement
Reference Information
Temperature
Operating
0°C to +40°C
Non-operating
-20°C to +60°C
Relative Humidity
Operating
20% to 80% relative humidity (%RH)
at up to +40°C, non-condensing
Non-operating
5% to 90% relative humidity (%RH) at
up to +60°C, non-condensing
Altitude
Operating
To 2,000m (6,561ft)
Non-operating
To 12,192m (40,000ft)
Vibration
Operating
2.65m/s2 (0.27Grms), 5Hz to 500Hz,
10 minutes per axis, three axes
Non-operating
22.3m/s2 (2.28Grms), 5Hz to 500Hz,
10 minutes per axes, three axes
Shock
Non-operating
294m/s2 (30G), half-sine, 11ms
duration
Summary of Contents for ACO-4400A
Page 1: ...ACO 4400A Automatic Changeover System for the SRG 4400 User Manual...
Page 8: ......
Page 12: ...iv Contents ACO 4400A User Manual Iss 03...
Page 18: ...1 6 Introduction ACO 4400A User Manual Iss 03...
Page 34: ...2 16 Physical Installation ACO 4400A User Manual Iss 03...
Page 54: ...4 10 Operating Basics ACO 4400A User Manual Iss 03...
Page 76: ...5 22 Front Panel Menu System ACO 4400A User Manual Iss 03...
Page 102: ...8 6 Connector Pinouts ACO 4400A User Manual Iss 03...
Page 106: ...9 4 Calibration Procedure ACO 4400A User Manual Iss 03...