ACO-2200 User Guide (v5.0)
Technical Specifications • 33
Technical Specifications
This chapter lists the electrical, mechanical, and environmental characteristics, as well as the national and
international standards to which the ACO-2200 complies.
Note that specifications are subject to change without notice.
General Characteristics
All listed specifications are guaranteed unless labeled with “Typical”. Typical specifications are provided for your
convenience, but are not guaranteed.
Performance Conditions
The electrical characteristics listed on the following pages are valid under the following conditions:
• The ACO-2200 must be in an environment where the temperature, altitude, humidity, and vibration conditions
are within the operating limits described in the section “
• The ACO-2200 must have a warm-up period of at least 20 minutes.
• The ACO-2200 must have been calibrated and adjusted at an ambient temperature b20°C and +30°C.
BNC Channels
Table 8.1 Technical Specifications — BNC Channels
Category
Performance Requirement
Notes
Input Connector Type
3 x 75ohm BNC per channel
The non-selected input is
automatically terminated
Return Loss (all inputs
and outputs)
270Mbps: <-11dB
1.5Gbps: <-4dB
3Gbps: <-1.4dB
Typical Amplitude
270Mbps: 800mV +/- 10%
1.5Gbps: 780mV +/- 10%
3Gbps: 660mV +/- 10%
Typical Rise & Fall
Time
270Mbps: 600ps/595ps +/- 10%
1.5Gbps: 155ps/145ps +/- 10%
3Gbps: 135ps/130ps +- 10%
Maximum Switched
Voltage
30V DC (30V AC)
Maximum Switched
Current
0.5A
Relay Switch Time
Based on Relay characteristics:
• Set time: typ. 3.5 ms,
• Release time: typ. 2.5 ms,
• Set/Release: max. 10mS
Insertion Delay
<1ns