Specifications
The information is this section is subject to change
without notice.
Resources
The number of resources specific to your server depends
on the model.
8-Channel
4-Channel
Resource
8
4
Video Inputs
8
4
Video Outputs
16
8
AES Audio Inputs
16
8
AES Audio Outputs
2
1
Analog Audio Outputs
Operating Temperature
The system has been qualified at an operational
temperature range of
13 to 35°C
(
55
to
95°F
) and a
non-condensing humidity range of
20
to
80%
.
Table 9: Safe Operation and Non-operating
Environmental Conditions
Non-operating
Operating
-40 to 65°C (-40 to
149°F)
5 to 55°C (41 to
131°F)
Temperature
5 to 95%
non-condensing
8 to 90%
non-condensing
Relative Humidity
35°C (95°F)
non-condensing
29.5°C (85°F)
non-condensing
Max. Wet Bulb
Temperature
15°C/hour
(59°F/hour)
15°C/hour
(59°F/hour)
Max. Temperature
Gradient
-300 to 12,200m
(-984 to 40,026ft.)
-300 to 3,048m
(-984 to 10,000ft.)
Altitude Range
Note:
Operator is responsible for providing sufficient ventilation
to maintain surface temperature below 40°C (104°F) at the center
of the top cover of the media drive.
Note:
Non-condensing conditions should be maintained at all
times.
Note:
Maximum storage period inside shipping package is one
year.