![Rosemount TankRadar Rex DAU 2100 Service Manual Download Page 94](http://html1.mh-extra.com/html/rosemount/tankradar-rex-dau-2100/tankradar-rex-dau-2100_service-manual_1487430094.webp)
Rosemount Tank Radar Rex
Chapter 4 Service
4-50
Service Manual
308012En, Ed.2
May 2013
Hardware installation
•
Connect the special three-wire cable between the RS-232 ports of
the FCUs. The cable shall be connected to the RS-232 port 2 con-
tact.
Figure 4-23. Connecting the RS-232 ports.
•
If a TRL/2 bus is connected to GB2, use an FCM board with spe-
cial jumper.
Note!
The old version of the standard FCM board can not be used at port 1
when redundant FCUs are used.
•
If an RS-232 bus is connected to GB2: use separate communica-
tion lines from the workstation to the “primary” and “backup” FCU,
respectively.
Figure 4-24. Using an RS-232 Group Bus connection.
Redundancy cable
Field Bus 1
Field Bus 2
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......