3-9
Rosemount Tank Radar Rex
Chapter 3 Device Description
Service Manual
308012En, Ed.2
May 2013
3.1.5
Write protection (Metrological Seal)
Part of the memory space in the Electronic Unit is of EEPROM type
(Electrically Erasable Programmable Read Only Memory). Program and
database updates are possible to perform over the Field Bus without
opening the Safety Enclosure.
A switch on the FCC board can be used to prevent unauthorized
changes in the RTG database. The switch can be sealed in the write-
inhibit position by using a special plastic cover.
For further information see 4.1.7
Figure 3-8. Metrological seal
As an option Rex can be equipped with the TRL/2 Metrological Seal.
consisting of a connection rod that activates the write protection switch.
Figure 3-9. Optional version of Metrological Seal.
Metrological seal
Write enable
Write inhibit
Rod
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......