2-9
Multichannel Installations
Several transmitters can be connected to a single master power supply
as shown in Figure 2-9. In this case, the system may be grounded only
at the negative power supply terminal. In multichannel installations
where several transmitters depend on one power supply and the loss of
all transmitters would cause operational problems, consider a back-up
battery or power supply that cannot be interrupted. The diodes shown
in Figure 2-9 prevent unwanted charging or discharging of the
back-up battery.
Figure 2-9. Multichannel Installations
Configuration Software
System Requirements
For the configuration software to function properly, the following
minimum PC requirements must be observed.
• 80386 or faster processor
• 1 MB free disk space
• 3.5-inch floppy disk drive
• Mouse or other pointing device
• 256 color display (recommended settings are 16-bit color at
1024 × 728 screen resolution)
• Microsoft Windows 3.1, Windows for Workgroups 3.11,
Windows 95, or Windows NT.
The configuration software is available in English, French, German,
Italian, Spanish, Chinese, Japanese, and Korean language versions.
The configuration software automatically selects the appropriate
language based on the language version of Windows.
NOTE
Close all currently running applications before starting the
installation procedure.
NOTE
Windows 98 is not compatible with this software.
Transmitter
No. 1
Transmitter
No. 2
R
Lead
R
Lead
R
Lead
Readout or
Controller
No.1
Readout or
Controller
No. 2
To Additional Transmitters
dc
Power
Supply
Backup Battery
30
44
-0
1
3
1
A