14. Raised face type for flanges.
15. Available for tank connection with flange.
16. Certificate includes all pressure retaining wetted metal parts.
17. For Probe Type 3A, 3B, 4A, 4B, 4S, and 4U, and PTFE-coated 5A.
18. Not available with PTFE covered probes.
19. Only available with HART 4-20 mA output (code H), standard operating temperature and pressure (code S), material of construction code 1, and
flexible single lead probes (probe type 5A or 5B). Not available with option codes QS and QT, and remote housing mounting (option code B1, B2, or
B3).
20. Available for SST, Alloy C-276, Alloy 400, and Duplex 2205 probes, type 2A, 4A, 4B, 4S, and 5A. Same disc material as probe material. For more
information, see
“Mounting a centering disc for pipe installations” on page 59
.
21. Available for probe types 2A, 4A, 4B, 4S, and 5A. Not available with Operating Temperature and Pressure code H or Material of Construction codes 7
and 8.