Digital Accuracy for Differential Configurations (dual-sensor option,
HART only)
• Sensor types are similar (e.g., both RTDs or both T/Cs): Digital Accuracy =
1.5 times worst case accuracy of either sensor type.
• Sensor types are dissimilar (e.g., one RTD, one T/C): Digital Accuracy =
Sensor 1 Ac Sensor 2 Accuracy.
Ambient Temperature Effect
Table A-1. Ambient Temperature Effect
Transmitters may be installed in locations where the ambient temperature is
between –40 and 85 °C (–40 and 185 °F).
To maintain excellent accuracy performance, each transmitter is individually
characterized over this ambient temperature range at the factory.
Sensor Options
Digital Accuracy per 1.0 °C (1.8 °F)
Change in Ambient
(1)
(1) Change in ambient is in reference to the calibration temperature of the transmitter (20 °C [68 °F]).
Range
D/A Effect
(2)
(2) Applies to HART / 4-20 mA devices.
2-, 3-, or 4- Wire RTDs
Pt 100 (
= 0.00385)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Pt 200 (
= 0.00385)
0.0023 °C (0.00414 °F)
Entire Sensor Input Range
0.001% of span
Pt 500 (
= 0.00385)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Pt 1000 (
= 0.00385)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Pt 100 (a = 0.003916)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Pt 200 (a = 0.003916)
0.0023 °C (0.00414 °F)
Entire Sensor Input Range
0.001% of span
Ni 120
0.0010 °C (0.0018 °F)
Entire Sensor Input Range
0.001% of span
Cu 10
0.015 °C (0.027 °F)
Entire Sensor Input Range
0.001% of span
Pt 50 (a = 0.00391)
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Pt 100 (a = 0.00391)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Cu 50 (a = 0.00426)
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Cu 50 (a = 0.00428)
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Cu 100 (a = 0.00426)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Cu 100 (a = 0.00428)
0.0015 °C (0.0027 °F)
Entire Sensor Input Range
0.001% of span
Thermocouples
Type B
0.014 °C
0.029 °C – (0.0021% of (T – 300))
0.046 °C – (0.0086% of (T – 100))
R
1000 °C
300 °C
R < 1000 °C
100 °C
R < 300 °C
0.001% of span
Type E
0.004 °C + (0.00043% of T)
0.001% of span
Type J
0.004 °C + (0.00029% of T)
0.004 °C + (0.0020% of absolute value T)
T
0
°C
T
0
°C
0.001% of span
Type K
0.005 °C + (0.00054% of T)
0.005 °C + (0.0020% of absolute value T)
T
0
°C
T
0
°C
0.001% of span
Type N
0.005 °C + (0.00036% of T)
All
0.001% of span
Types R
0.015 °C
0.021 °C – (0.0032% of T)
T
200
°C
T
200
°C
0.001% of span
Types S
0.015 °C
0.021 °C – (0.0032% of T)
T
200
°C
T
200
°C
0.001% of span
Type T
0.005 °C
0.005 °C + (0.0036% of absolute value) T)
T
0
°C
T
0
°C
0.001% of span
DIN Type L
0.0054 °C + (0.00029% of T)
0.0054 °C + (0.0025% of absolute value T)
T
0
°C
T
0
°C
0.001% of span
DIN Type U
0.0064 °C
0.0064 °C + (0.0043% of absolute value T)
T
0
°C
T
0
°C
0.001% of span
Type W5Re/W26Re
0.016 °C
0.023 °C + (0.0036% of T)
T
200
°C
T
200
°C
0.001% of span
GOST Type L
0.005 °C
0.005 °C + (0.003% of T)
T ³ 0 °C
T < 0 °C
0.001% of span
Millivolt Input
0.00025 mV
Entire Sensor Input Range
0.001% of span
2-, 3-, 4-wire Ohm Input
0.007 ohms
Entire Sensor Input Range
0.001% of span