Reference Manual
300550EN, Rev AA
December 2010
Rosemount 2240S
A-4
Appendix A. Reference Data
A.3 ORDERING INFORMATION
Model (Pos 1) Product Description
Note
2240S
Multi-input Temperature Transmitter
Code (Pos 2)
Performance Class
Note
P
Premium: ±0.05 °C(0.09 °F) instrument accuracy
Code (Pos 3)
Number of Temperature Sensor Inputs
Note
16
Up to 16xRTD spot elements
(1)
08
Up to 8xRTD spot elements
04
Up to 4xRTD spot elements
00
None
(2)
Code (Pos 4)
Leads per Temperature Element
Note
4
4-wire or 3-wire (individual or common return)
3
3-wire (individual or common return)
0
None
For water level, no temperature sensors
Code (Pos 5)
Auxiliary Inputs
Note
A
Rosemount 765 temperature and water level sensor input
0
None
Code (Pos 6)
Tankbus: Power and Communication
Note
F
Bus powered 2-wire F
OUNDATION
™ fieldbus (IEC 61158)
Code (Pos 7)
Hazardous Location Certification
Note
I1
ATEX Intrinsic Safety
I5
FM-US Intrinsic Safety
I6
FM-Canada Intrinsic Safety
I7
IECEx Intrinsic Safety
KA
ATEX Intrinsic FM-US Intrinsic Safety
(3)
KC
ATEX Intrinsic IECEx Intrinsic Safety
KD
FM-US Intrinsic FM-Canada Intrinsic Safety
NA
No Hazardous Location Certification
Code (Pos 8)
Custody Transfer Type Approval
Note
0
None
Code (Pos 9)
Housing
Note
A
Standard enclosure
Polyurethane-covered aluminum; IP 66/67
Code (Pos 10) Cable/Conduit Connections
Note
1
1/2–14 NPT
Female thread. Includes 2 plugs
2
M20 x 1.5 Adapters
Female thread. Includes 2 plugs, and 3 adapters
G
Metal cable glands (1/2–14 NPT)
Min. temperature -20
˚
C (-4
˚
F). ATEX / IECEx
Exe approved. Includes 2 plugs, and 3 glands
(4)
E
Eurofast male connector and 1/2–14 NPT
Includes 2 plugs
M
Minifast male connector and 1/2–14 NPT
Includes 2 plugs