Orion Extender Installation and Operation Manual
56
USB 2.0 Only
Embedded Upgrade Card Failure
The steps to troubleshoot this failure utilize the Status LEDs on the
USB 2.0 Only Embedded Upgrade Card
as described on page
. The LEDs mentioned in the table below correspond to the Status LEDs shown in
Figure 35. Status LEDs on USB-2.0 Only Embedded Upgrade Card
Symptom
Diagnosis
Solution
Transmitter and
Receiver: LED 3 off
No connection to CPU
Check connection of USB cable to CPU;
use another USB port if necessary
Unplug USB from CPU and cycle power
to the CPU. Re-plug USB cable to CPU
Transmitter and
Receiver: LED 2 off
No connection between
Transmitter and Receiver
Check interconnect cable and connectors
Transmitter and
Receiver: LED 2 off and
USB 2.0 device does not
function
No USB 2.0 device
Connect USB 2.0 device
USB 2.0 device is not supported
Check installation at the CPU; ensure
necessary drivers are installed
New connection of the USB 2.0 device
Contact Rose Electronics, if necessary
Table 27.Troubleshooting USB 2.0 Only Embedded Upgrade Card Failure
First Generation USB 2.0 Standalone Upgrade Card Failure
The steps to troubleshoot this failure utilize the Status LEDs on the
First Generation USB 2.0 Standalone
, as described on page
. The LEDs mentioned in the table below correspond to the Status
LEDs shown in
Figure 36. Status LEDs on First Generation USB 2.0 Standalone Upgrade Card
page.
Symptom
Diagnosis
Solution
Transmitter: All LEDs off No connection to CPU
Check connection of USB cable to CPU;
use another USB port if necessary
Unplug USB from CPU and cycle power
to the CPU. Re-plug USB cable to CPU
Receiver: LED 3 Red
No connection between
Transmitter and Receiver
Check interconnect cable and connectors
Receiver: LED 3 flashing
Green / Light Blue and
USB 2.0 device does not
function
No USB 2.0 device
Connect USB 2.0 device
USB 2.0 device is not supported
Check installation at the CPU; ensure
necessary drivers are installed
New connection of the USB 2.0 device
Contact Rose Electronics, if necessary
Table 28.Troubleshooting First Generation USB 2.0 Standalone Upgrade Card Failure
Summary of Contents for Orion XTender OR2-SRDFSUD1D