Page 1: ...Ropox FlexiBasic 30 63XXX User manual Mounting instruction This folder must always be kept with the product PDF 5996 28 05 2019 PA 2004 00634 ...

Page 2: ...fascia 12 6 7 Mounting the side fascia 12 6 8 Adjusting the worktop support arms 12 6 9 Mounting of distance plates 1cm for skirting board 12 6 10 Mounting the flexible water connections and waste hoses 12 6 11 Adjusting the height of the worktop by using the Jack Up unit 13 6 12 Mounting the supporting feet 13 6 13 Mounting the covers for the legs 13 6 14 Mounting the concealment panels 13 7 PERF...

Page 3: ...ers for the vertical legs FlexiBasic will give you a quick and easy adjustment of the frame by using the jack up The frame can be rebuild to a FlexiManual or a FlexiElectric at a later stage The correct use operation and inspection are decisive factors for efficient and safe performance 2 Compliance with EU Directives This product has CE marking and thus complies with the basic safety requirements...

Page 4: ...djustment 65 95 cm without worktop Material Welded steel tubes St 37 Aluminium alloy 606045 T6 Plastic components Surface treatment Chromite Powder coating Standard RAL 9010 mat white Max load of frame 150 kg evenly distributed over the entire worktop Temperature 5 45 C Air humidity 5 85 non condensing Complaints See complaints page 20 Manufacturer Ropox A S DK 4700 Naestved Tel 45 55 75 05 00 ...

Page 5: ... for the fixed feed pipes on the wall to be pointing down at a height of max 30 cm This will ensure that the flexible feed pipes will always flex in a neat curve close to the wall without kinking A 90 degree valve with a 1 2 exposed thread is recommended For worktops with cut outs the distance from either side of the worktop should be considered as shown on the illustration L 60 300 cm A MAX 50 cm...

Page 6: ...op 62 cm deep Max Permissible load at the Flexi frame is 150 Kg evenly distributed In this example we have put the max Load in the front of the worktop 150 x 62 Tension upper bolts 35 x 2 133 Kg bolt Safety factor must be used Safety factor 1 133 Kg bolt Safety factor 2 266 Kg bolt Safety factor 3 399 Kg bolt Under normal circumstances the load will be distributed to the two legs 4 bolts ...

Page 7: ...y check that all parts have been provided See list of components from page15 See also mounting instructions page 11 The equipment should always be assembled by competent personnel 6 1 1 6 2 2 6 2 1 8 cm 6 3 2 6 4 1 8 cm 6 3 3 6 3 1 6 1 2 2 5 43 5cm 9 cm Max 50 cm ...

Page 8: ...Side 8 6 4 2 6 6 1 6 5 3 6 6 2 6 5 1 6 7 1 6 8 1 2 5 cm 6 5 2 ...

Page 9: ...Side 9 6 9 1 6 8 2 6 11 2 6 11 3 6 11 4 6 10 1 6 11 1 ...

Page 10: ...f Worktop Lower consealment panel Distance between feet 6 14 4 8 cm 8 cm 40 cm Lower consealment panel in case of supporting feet 3 cm L Length of Worktop 6 12 1 6 12 2 6 13 1 6 13 2 6 14 2 45 cm L Length of Worktop Upper consealment panel ...

Page 11: ...m supports that are positioned on top of the legs see 6 8 1 We recommend a maximum distance between the support arms of 60 cm in order to obtain optimum stability 6 3 Mounting the frame on the wall 6 3 1 Place the frame against the wall and align it Adjust the two threaded bolts under the legs to ensure that the frame is horizontal 6 3 2 To obtain the correct height 65 95 cm without worktop adjust...

Page 12: ...the support arm 6 7 Mounting the side fascia 6 7 1 Furniture fittings are provided with the frame to keep the wooden side fascia up against the worktop 6 8 Adjusting the worktop support arms 6 8 1 After placing the worktop on the frame you may have to compensate for the weight of the worktop if the frame is no longer horizontal from the wall to the front fascia 6 8 2 By means of the two lower scre...

Page 13: ...ree legs three bolts must be fastened 6 11 4 The inner leg is bevelled so that the upper frame can only move down slowly as the bolt is loosened 6 12 Mounting the supporting feet Option 6 12 1 Remove the adjusting screw of the leg 6 12 2 Fit the foot and the extension to the leg with the screws provided and tighten the screws 6 13 Mounting the covers for the legs Option 6 13 1 Press the covers con...

Page 14: ...k that the mounting instructions have been observed 2 Check that all bolts have been tightened 3 There must be no load on the frame 4 There must be nothing preventing the frame from moving freely within the height adjustment range 65 95 cm 5 If all these tests are ok the FlexiBasic is ready for use 8 List of components for FlexiBasic for worktop 60 300 cm Legs standard height 65 95 cm 30 63400 Len...

Page 15: ...30 67622 Length of worktop 60 104 cm 2 pcs Length of worktop 105 204 cm 4 pcs Length of worktop 205 254 cm 5 pcs Length of worktop 255 300 cm 7 pcs Distance plate 1 cm 30 67680 For skirting board 1 pc Distance bracket 7 cm 30 67672 For void behind the frame 1 pc Cover 30 67735 Length of worktop 60 300 cm 2 pcs Cover for supporting foot 30 67737 Length of worktop 60 300 cm 2 pcs Fittings for concea...

Page 16: ...original spare parts as replacement parts If other spare parts are used the guarantee may become void 11 Cleaning and maintenance 11 1 Cleaning The frame may get dirty during use It is very important to clean the frame as described in these instructions Clean the frame with a damp cloth using lukewarm water and ordinary cleaning agents Do not use Corrosive abrasive liquids or abrasive cloths brush...

Page 17: ...peration and maintenance Service and maintenance Serial No Date Sign Remarks Service and maintenance Serial No Date Sign Remarks Service and maintenance Serial No Date Sign Remarks Service and maintenance Serial No Date Sign Remarks ...

Page 18: ...r installation of the frame the worktop will be loaded This deflection may be balanced by repeating item 6 8 Adjusting the Support arms of the mounting instructions Also check that the legs are vertical see item 6 3 c The height of the frame cannot be adjusted adjustment seems very difficult 1 Check that the frame is not overloaded 2 Check that the frame moves freely and that no objects have been ...

Page 19: ...ards DIRECTIVES and REGULATIONS Regulation EU 2017 745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices STANDARDS DS EN ISO 13485 2016 Medical devices Quality management systems Requirements for regulatory purposes DS EN ISO 14971 2012 Medical devices Application of risk management to medical devices DS EN 12182 2012 Assistive products for persons with disability Ge...