11.6.2 Acknowledgement message
After each START/STOP command, the RESISTRON
®
Temperature Controller RES-5009 automatically sends
an acknowledgement message (CAN message address 0009). It contains the current actual value and the most
important status information:
11.6.3 Alarm /AUTOCAL status
Bit no.
Name
Meaning
0…8
Actual value
Value of the current actual value (in °C)
9
Prefix
Prefix of the actual value. 0: positive, 1: negative
10…11
Setpoint no.
Number of the last setpoint used (0…3)
12
Control active
0: Measurement mode
1: Control mode
13
“Temperature
OK“ bit
0: Actual value is outside the specified temperature monitoring band
1: Actual value is inside the specified temperature monitoring band
14
Alarm
0: no alarm
1: Alarm active
15
Autocal blocked
0: AUTOCAL function possible
1: AUTOCAL function not possible (cooling off phase)
Bit no.
Name
Meaning
0…9
Error code
three-digit error code
10…11
Error action
0: Perform RESET
1: Perform AUTOCAL
2: Check configuration
12…15
Autocal status
0: AUTOCAL function possible (not active and not blocked)
1: AUTOCAL function is active
2: Check for falling actual value
3: Wait until AUTOCAL request is withdrawn
4: Wait whether AUTOCOMP will be started
5: AUTOCOMP function active
6: AUTOCAL function blocked, because heating band is still warm
7: AUTOCAL function blocked, because test mode is active
8: AUTOCAL function blocked, because START is active
9: AUTOCAL function blocked, because PREHEAT is active
10: AUTOCAL function blocked, because DETACH is active (not used)
11: AUTOCAL function blocked, because RESET is active
12: AUTOCAL function blocked, because Alarm is active
13: reserved
14: AUTOCAL function is aborted