Factory settings
Page 34
RES-5007
Version 1
9
Factory settings
The RESISTRON
®
temperature controller RES-5007 is configured as follows from the factory:
[X] Only with ROPEX visualisation software
Internal device error
- Hardware error (replace controller)
- Slide switch for alarm relay defective or not in correct posi-
tion
- Network voltage missing
Rotary encoder switch
for
Heating element alloy
and
Temperature range
(June 2003 and later)
Heating element alloy: Alloy A20
Temperature range: 300 °C
Maximum temperature: 300 °C
Rotary encoder switch: Position “0”
Slide switch
for
Alarm output
Alarm output active in case of alarm
Automatic
Phase correction
(AUTOCOMP)
[X]
AUTOCOMP: OFF
Measurement impulse
duration
[X]
Measurement impulse duration: 1.7 ms
Temperature
diagnosis
[X]
Temperature diagnosis: OFF
Heat-up time
monitoring
[X]
Heat-up time monitoring: OFF
Malfunc-
tion range
Explanations
Possible causes
SWITCH POS.
1
0
4
5
8
9
300°C
0
5
1
2
3
4
6
7
8
9
0
5
1
2
3
4
6
7
8
9
AUX
CONF
IGURA
TIO
N
ALARM
O
UT
PUT
ENERG
IZED
(AT
A
LA
RM)
DE-E
NE
RG
IZ
ED