Mounting and Installation
Version 1
RES-5007
Page 13
6.6
Supply voltage
To provide power to the RES-5007, voltage of 24 VDC must be applied to the terminals 12+13. The maximum cur-
rent draw is 1.0 A. The supply voltage input is protected against faulty polarisation.
6.7
Connection diagram (standard)
RES-5007
(also with MOD 01)
R
Impulse
transformer
9
8
4
3
2
1
UR
Heat-
sealing
band
sec.
U2
prim.
U1
twisted
Current transfomer
11
10
IR
14
12
7
6
5
16
17
15
13
18
=
=
RESET
24
signal
VDC
START HEAT
(
)
24
signal
VDC
Protective con-
ductor connection
AUTOCAL
24
signal
VDC
ALARM OUTPUT
+24 VDC
PE
+24 VDC
REFERENCE
VOLTAGE
OUTPUT U
REF
+10 VDC
ANALOG OUTPUT
(actual value)
+0...10 VDC
ANALOG INPUT
(setpoint)
+0...10 VDC
24 VDC POWER
SUPPLY
GND
Line f
r
ilte
LINE