10.14 Hold mode
The behaviour of the digital indication of the ACTUAL temperature in the home position can be changed with
step 206 in the Settings menu.
The following settings are possible:
1.
"OFF" (Factory setting)
If the main menu is visible on the display, the real ACTUAL temperature is always indicated.
2.
"ON"
If the display is in the home position, the ACTUAL temperature that was valid at the end of the last heatsealing
phase is always indicated as a digital value. When the controller is switched on - or after an alarm is
acknowledged - the real ACTUAL temperature is indicated until the end of the first heating phase.
3.
"2 s"
This setting causes the current ACTUAL temperature to be displayed as a digital value for an additional
2 seconds at the end of a heatsealing phase. This temperature is then indicated again in real time until the end
of the next heating phase.
Hold mode only affects the digital value on the display. The ACTUAL temperature in real time is
always indicated, regardless of the setting, by the dynamic bar and the actual value output.
!