Controller functions
Page 38
RES-408
Version 1
11.6
Temperature setting (set point selection)
The heatsealing temperature can be set on the RES-408 controller with the setting in the "SH" [
S
eal
H
eat] menu
step.
The set point selected for the heatsealing temperature must be greater than 40°C. If not, the heatsealing band is
not heated when the "START" signal is activated or the "HAND" key is pressed. The 1…39°C setting range is not
available on controllers manufactured as of June 2006.
11.7
Temperature indication / actual value output
If the display is in the home position ("°C"), the ACTUAL temperature is indicated.
The heating and control process can thus be observed at any time.
AL
[
AL
arm]
Alarm menu
If an alarm is indicated, the controller shows the
Alarm menu. Some faults can be acknowledged by
pressing the "RESET" key. In this case, the con-
troller switches back to the home position.
If the fault can be rectified by executing the
AUTOCAL function, you can select the "AC"
[
A
uto
C
al] menu step directly by briefly pressing the
"MENU" key (<2s). You can then activate the
"AUTOCAL" function by pressing the "ENTER" key.
This step is included in the menu struc-
ture of all controllers manufactured up to
May 2006. If no error message is indicated, the
display shows "000". On controllers manufac-
tured as of June 2006, this step only appears if
an alarm is indicated.
Name
Description
Setting range
!
HOLD
PREHEAT
SEALHEAT
ENTER
HAND
RESET
ROPEX
T-408