Startup and operation
Page 26
RES-408
Version 1
10.2.2 Configuration of the rotary coding switch for the temperature range and alloy (as
of June 2006)
This configuration is set as standard on all controllers manufactured as of June 2006. The settings
are only possible on older controllers in conjunction with MOD 37 (
If the switch is set to "9" (as of June 2006), other temperature ranges and alloys can be selected in the ROPEX
visualization software (
see section 11.19 "Diagnostic interface / visualization software (as of June 2006)" on
10.2.3 Configuration of the alarm relay
If the plug-in jumper is not inserted on controllers manufactured up to May 2006, the alarm relay is
permanently energized (alarm contact between terminals 13 and 14 closed). The other functions of
the controller (e.g. heating the heatsealing band, AUTOCAL etc.) are not affected.
If the plug-in jumper is not inserted on controllers manufactured as of June 2006 - or if it is incorrectly
inserted - an error message appears when the controller is switched on (
If the "Alarm relay de-energized by alarm/PC CONFIGURATION" position is selected (as of June 2006), the
behavior of the alarm output can be configured more finely in the ROPEX visualization software (
see
section 11.19 "Diagnostic interface / visualization software (as of June 2006)" on page 51).
0
5
1 2
3
4
6
7
8
9
0
5
1
2
3
4
6
7
8
9
Switch
position
0
1
4
5
8
300°C
300°C
500°C
500°C
300°C
1100ppm/K
780ppm/K
1100ppm/K
780ppm/K
3500ppm/K
e.g. A20
e.g. L
e.g. A20
e.g. L
Temp.
range
Temp.
coefficient
Band
alloy
0 = Factory settings
SWITCH POS.
1
0
4
5
8
9
TEMP. RANGE
300°C
300°C
500°C
500°C
300°C
PC CONFIGURATION
ALLOY
780ppm/K
1100ppm/K
(L)
(A20)
1100ppm/K
(A20)
780ppm/K
3500ppm/K
(L)
9
PC-CONFIGURATION
!
0
5
1
2
3
4
6
7
8
9
Alarm relay de-
energized by alarm/
PC-CONFIGURATION.
Alarm relay energized
by alarm.
(factory setting)
CONFIGURATION
ALARM OUTPUT
DE-ENERGIZED / PC
AT ALARM
ENERGIZED
!