Technical data
Page 73
UPT-6011
Version 5
10
Technical data
Type of construction
Housing for installation in an electrical cabinet
Snaps onto a standard top hat rail (TS35 rail, 35 mm) acc. to DIN EN 50022
Dimensions: 90 x 75mm; depth: 135 mm (incl. terminals)
Line voltage
110 VAC -15%…300 VAC +10%
Connected between neutral conductor and one line conductor
or
until 01/2012: 110 VAC -15%…415 VAC +10%
as from 02/2021: 110 VAC -15%…480 VAC
1
+10%
Connected between two line conductors
The voltage between the line conductor and ground must not be more
than 300 VAC.
Power supply system
Balanced TN or TT system
Installation category III
Operation in potential-free systems (e.g. an IT system) is only per-
mitted after consultation with ROPEX.
Line frequency
47…63 Hz, automatic adjustment to frequencies in this range
Current consumption
(primary current of
impulse
transformer)
I
max
= 5A (duty cycle = 100%)
I
max
= 25A (duty cycle = 20%, cycle duration 1 min)
24 VDC supply
voltage
Terminals 5+7
24 VDC, Imax = 200 mA (control mode), 1 A (switch-on current)
Tolerance: ±10%
SELV or PELV supplied from max. 300 VAC, Cat II
Measuring range
Secondary voltage U
R
:
0.4…120 VAC
Secondary current I
R
:
30…500 A (with PEX-W4/-W5 current transformer)
ROPEX Application Report
EtherNet/IP
TM
inter-
face
2 Ethernet switch ports RJ45
Wiring: IEC 61784-5-3
Data transfer rate: 10 or 100 MHz
Data transport layer: Ethernet II, IEEE 802.3
Addressing: DHCP or selectable with rotary coding switch
ACD and DLR support: Yes
Heating element type
and temperature
range
The temperature range and temperature coefficient settings can also be specified
in the ROPEX visualization software (
section 8.12 "USB interface for visualiza-
" on page 65) in addition to using the rotary coding
switch or via the EtherNet/IP
TM
interface (see below):
Temperature range:
200 °C, 300 °C, 400 °C, or 500 °C
Temperature coefficient: 400…4000 ppm/K (variable setting range)
Two different ranges can be set using the rotary coding switch or via the EtherNet/
IP
TM
interface:
Temperature coefficient 1700 ppm/K, 0…300 °C (CIRUS)
Temperature coefficient 1700 ppm/K, 0…500 °C (CIRUS)
!
!