34
E11
No water
Yellow lamp (lack water)
always on
E12
No gas
Red lamp always on
E13
Under voltage
Yellow lamp (thermal
protection) always on
E14
Over voltage
Yellow lamp (thermal
protection) always on
E15
Over current
Yellow lamp (thermal
protection) always on
E16
Wire feeder over load
Switch
E20
Button fault on operating panel when
switch on the machine
Yellow lamp (thermal
protection) always on
E21
Other faults on operating panel when
switch on the machine
Yellow lamp (thermal
protection) always on
E22
Torch fault when switch on the
machine
Yellow lamp (thermal
protection) always on
E23
Torch fault during normal working
process
Yellow lamp (thermal
protection) always on
Accessory
E30
Cutting torch disconnection
Red lamp blink
E31
Water cooler disconnection
Yellow lamp (lack water)
always on
Communication
E40
Connection problem between wire
feeder and power source
E41
Communication error