18
•
4.3. Welding parameters
Welding current
(
A
)
Welding volt
(
V
)
Wave control
Wire speed
φ0.8
φ1.0
φ1.2
60A
16
~
17V
0-2
3--4
80A
17
~
18V
0-2
4--5
3--4
100A
17
~
19V
2-3
5--6
3--5
2--3
120A
17
~
19V
2-3
6--7
4--5
3--4
150A
18
~
20V
3-5
7--9
4--6
4--5
180A
20
~
23V
3-6
8-10
6--8
5--6
220A
21
~
24V
4-6
7--10
6--8
250A
22
~
26V
6-8
7-9
•
4.4. Operation environment
Height above sea level ≤1000 M
Operation temperature range -10
~
+40
℃
.
Air relative humidity is below 90 %( 20
℃
).
Preferable site the machine some angles above the floor level, the maximum angle does
not exceed 15
℃
.
Protect the machine against heavy rain or in hot circumstance against direct sunshine.
The content of dust, acid, corrosive gas in the surrounding air or substance can not exceed
normal standard.
Take care that there is sufficient ventilation during welding. There is at least 30cm free
distance between the machine and wall.